1 Introduction
1.1 Safety
1.1.1 Software Version
FCM 300 Series
Design Guide
Software version: 3.1x
This Design Guide can be used for all FCM 300 Series frequency
converters with software version 3.1x.
The software version number can be seen from parameter 624
Software version no.
Table 1.1
1.1.2 Disposal Instruction
Equipment containing electrical
components may not be disposed of
together with domestic waste.
It must be separately collected with
electrical and electronic waste according
to local and currently valid legislation.
Table 1.2
1.1.3 Symbols
The following symbols are used in this Design Guide and
require special attention.
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
NOTICE
Indicates highlighted information that should be
regarded with attention to avoid mistakes or operate
equipment at less than optimal performance.
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may
also be used to alert against unsafe practices.
1.1.4 General warnings
NOTICE
All operations must be carried out by appropriately
trained personnel.
Use all lifting facilities provided e.g. both lifting points if
fitted or single lifting point if fitted*.
Vertical lifting - Prevent uncontrolled rotation.
Lift machine - Do not lift other equipment with motor
lifting points only.
Before installation check for fan cover damage, shaft
damage, foot/mounting damage, and loose fasteners.
Check nameplate details.
Ensure level mounting surface, balanced mounting, not
misaligned.
Gaskets, and/or sealants, and guards must be correctly
fitted.
Correct belt tension.
Please observe derating rules, see
*Note: maximum hand lift is 20 kg below shoulder, but
above ground level. Max. gross weights:
-
Frame size 80: 15 kg
-
Frame size 90 & 100: 30 kg
-
Frame size 112: 45 kg
-
Frame size 132: 80 kg
WARNING
The voltage on the FC motor is dangerous when the
motor is connected to mains. Incorrect installation of the
FC motor may lead to material damage or serious injury,
or it may be fatal.
Consequently, the instructions in this manual as well as
national and local rules and safety regulations must be
complied with.
Touching the electrical parts may be fatal, even after the
mains supply has been disconnected. Wait at least 4
minutes.
- Installation must be fused and isolated correctly.
- Covers and cable entries must be fitted.
WARNING
By altitudes above 2 km, please contact
Danfoss Drives regarding PELV.
Introduction
VLT
®
DriveMotor FCM Series
4
MG03BA02 - VLT
®
is a registered Danfoss trademark
1
1
Содержание VLT Brook Crompton Motor FCM 300
Страница 1: ...MAKING MODERN LIVING POSSIBLE Design Guide VLT Brook Crompton Motor FCM 300 www danfoss com drives...
Страница 2: ......
Страница 26: ...Illustration 2 5 Installation VLT DriveMotor FCM Series 24 MG03BA02 VLT is a registered Danfoss trademark 2 2...
Страница 37: ...Programming VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 35 3 3...
Страница 101: ...Index VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 99...
Страница 102: ...www danfoss com drives MG03BA02 175R0087 MG03BA02 Rev 2011 12 22...