under both Warning and Alarm, this can mean that a
warning precedes the alarm. It can also mean that it is
possible to program whether a given fault is to result in a
warning or an alarm. After a trip, alarm and warning will
flash, but if the fault is removed, only alarm will flash. After
a reset, the FC motor will be ready to start operation
again.
No.
Description
Warning
Trip Alarm
Trip locked
2
Live zero fault (LIVE ZERO ERROR)
X
X
4
Phase loss (MAINS PHASE LOSS)
X
X
X
5
Voltage warning high (DC LINK VOLTAGE HIGH)
X
6
Voltage warning low (DC LINK VOLTAGE LOW)
X
7
Overvoltage (DC LINK OVERVOLT)
X
X
8
Undervoltage (DC LINK UNDERVOLT)
X
9
Inverter overload (INVERTER TIME)
X
X
11
Motor thermistor (MOTOR THERMISTOR)
X
12
Torque limit (TORQUE LIMIT)
X
13
Overcurrent (OVERCURRENT)
X
X
14
Earth fault (EARTH FAULT)
X
X
15
Supply fault (SWITCH MODE FAULT)
X
X
16
Short-circuit (CURR.SHORT CIRCUIT)
X
X
17
Standard bus timeout (STD BUS TIMEOUT)
X
X
18
HPFB bus timeout (HPFB TIMEOUT)
X
X
33
Out of frequency range (OUT FREQ RNG/ROT LIM)
X
34
HPFB error (HPFB ALARM)
X
X
35
Inrush fault (INRUSH FAULT)
X
X
36
Overtemperature (OVERTEMPERATURE)
X
X
37
Internal error (INTERNAL ERROR)
X
X
Table 4.4 Warnings and Alarms
4.2.2 What if the Motor does not Start?
The LCP may be set for local stop. If so, the motor does
not start when you disconnect the LCP. To make the
motor start an LCP has to be connected, - there is no
other way, and the MCT 10 Setup Software will not tell
you what is wrong or what to do. So in case of problems
follow the procedure stated below:
WARNING
Warning:
Extreme care must be taken when operating
the unit with open lid.
Green
Yellow
Red
Action
LED 302
LED 301
LED 300
OFF
OFF
OFF
Apply power
ON
OFF
OFF
Apply start and reference signals
ON
OFF
ON
Apply and remove reset signal
ON
ON
ON
Switch off power until all LED's have turned off
For further information see the quick setup MG03FXYY.
Table 4.5
1.
Make sure no parameters have been changed
from initial delivery status (factory setting). Use
the Local Control Panel or serial port to reset to
factory setting. Make sure that parameter 002 is
set for remote (if not, the yellow LED 301 will be
flashing slowly.
2.
Make sure no STOP command has been made via
the optional control panel keyboard (local stop,
yellow LED 301 flashing slowly *), Control panel
STOP can only be restarted by the Control Panel
START button.
All about FCM 300
VLT
®
DriveMotor FCM Series
MG03BA02 - VLT
®
is a registered Danfoss trademark
85
4
4
Содержание VLT Brook Crompton Motor FCM 300
Страница 1: ...MAKING MODERN LIVING POSSIBLE Design Guide VLT Brook Crompton Motor FCM 300 www danfoss com drives...
Страница 2: ......
Страница 26: ...Illustration 2 5 Installation VLT DriveMotor FCM Series 24 MG03BA02 VLT is a registered Danfoss trademark 2 2...
Страница 37: ...Programming VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 35 3 3...
Страница 101: ...Index VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 99...
Страница 102: ...www danfoss com drives MG03BA02 175R0087 MG03BA02 Rev 2011 12 22...