Pa
r.
No.
#
Pa
ra
m
eter descri
pti
on
De
fau
lt va
lue
4-se
t-up
FC 302
only
Ch
an
ge
du
rin
g o
p-
erat
ion
Conve
r-
sion
inde
x
Typ
e
16
-0* Gen
eral St
atu
s
16-
00
Co
ntrol Word
0 N
/A
Al
l s
et
-u
ps
FA
LS
E
0
V2
16-
01
Re
fe
re
nc
e [Un
it]
0.
000
Re
fere
nceFe
ed
ba
ckUnit
Al
l s
et
-u
ps
FALSE
-3
In
t32
16-
02
Re
fere
nc
e
%
0.
0 %
All
set-
up
s
FALSE
-1
In
t1
6
16-
03
St
at
us
W
or
d
0 N
/A
Al
l s
et
-u
ps
FALSE
0
V2
16-
05
Mai
n Ac
tu
al
Val
ue
[%]
0.00
%
All
set-
up
s
FALSE
-2
N2
16-
09
Cu
stom R
eadout
0.
00
Cust
omRea
dou
tUnit
Al
l s
et
-u
ps
FALSE
-2
In
t32
16
-1* Motor
St
atu
s
16-
10
Po
w
er
[k
W
]
0.
00 kW
Al
l s
et
-u
ps
FALSE
1
In
t32
16-
11
Po
w
er
[hp]
0.
00
hp
Al
l set-
up
s
FALSE
-2
In
t3
2
16-
12
Motor v
ol
tag
e
0.0
V
Al
l s
et
-u
ps
FALSE
-1
Ui
nt16
16-13
Fre
que
ncy
0.0 Hz
Al
l se
t-u
ps
FALSE
-1
Ui
nt16
16-
14
Mo
tor Curre
nt
0.0
0 A
Al
l s
et
-u
ps
FALSE
-2
In
t32
16-
15
Freq
uency
[%]
0.00
%
All
set-
up
s
FALSE
-2
N2
16-
16
To
rq
ue
[N
m
]
0.
0 N
m
Al
l s
et
-u
ps
FALSE
-1
In
t16
16-
17
Sp
ee
d
[RP
M
]
0 RP
M
All
set-
up
s
FALSE
67
In
t3
2
16-
18
Motor Therm
al
0 %
Al
l s
et
-u
ps
FALSE
0
Ui
nt8
16-
19
KTY
senso
r temp
er
ature
0 °C
Al
l set-
up
s
FALSE
10
0
In
t1
6
16-
20
Motor Ang
le
0 N
/A
Al
l s
et
-u
ps
TR
UE
0
Ui
nt16
16-
22
To
rq
ue
[%
]
0 %
Al
l s
et
-u
ps
FALSE
0
In
t16
16
-3* Dr
iv
e
Stat
us
16-
30
DC Link Vo
lta
ge
0 V
Al
l se
t-
up
s
FA
LS
E
0
U
in
t1
6
16-
32
Br
ak
e En
ergy
/s
0.
000
kW
Al
l s
et
-u
ps
FALSE
0
Ui
nt32
16-
33
Brake
E
ne
rg
y /
2 min
0.
000
kW
Al
l set-
up
s
FALSE
0
U
in
t32
16-
34
Heatsink Temp.
0 °C
Al
l s
et
-u
ps
FALSE
10
0
Ui
nt8
16-
35
Inverte
r The
rmal
0
%
All
set-
up
s
FALSE
0
U
int8
16-
36
Inv.
Nom.
Cu
rrent
Ex
pressio
nLimit
Al
l s
et
-u
ps
FALSE
-2
Ui
nt32
16-
37
Inv. Max.
Current
Exp
re
ssion
Li
mit
All
se
t-u
ps
FALSE
-2
Ui
nt32
16-
38
SL
C
ont
ro
lle
r
St
at
e
0 N
/A
Al
l s
et
-u
ps
FALSE
0
Ui
nt8
16-39
Co
ntrol Card Te
mp.
0 °C
Al
l se
t-u
ps
FALSE
10
0
U
int8
16-
40
Lo
ggi
ng B
uffe
r F
ull
[0
] N
o
Al
l s
et
-u
ps
TR
UE
-
Ui
nt8
16
-5* Re
f. & Fe
edb.
16-
50
Extern
al R
efe
ren
ce
0.
0 N/A
Al
l s
et
-u
ps
FALSE
-1
In
t16
16-
51
Pul
se R
efere
nce
0.
0 N/A
All
set-
up
s
FALSE
-1
In
t1
6
16-
52
Feedb
ack [U
ni
t]
0.
000
Re
fere
nceFe
ed
ba
ckUnit
Al
l s
et
-u
ps
FALSE
-3
In
t32
16
-5
3
Di
gi
Pot
Ref
eren
ce
0.
00
N/A
Al
l se
t-u
ps
FALSE
-2
In
t16
4.3.1
5
16-*
*
Dat
a Readouts
VLT
®
Automation Drive FC 300
Instruction Manual High Power
4 How to Program
MG.33.U2.22 - VLT
®
is a registered Danfoss trademark
4-27
4