X64 Xcelera-HS PX8 User's Manual
Technical Specifications
•
81
TTL Shaft Encoder to RS-422 Input Block Diagram
RS-422 (+) input
RS-422 (-) input
FG/system GND
DC
+1 to +2
volts
TTL signal source
GND
Frame Grabber System
Connecting TTL Signals to RS-422
Inputs
Figure 40: Connecting TTL to RS-422 Shaft Encoder Inputs
•
RS-422 (-) input is biased to a DC voltage from +1 to +2 volts.
•
This guarantees that the TTL signal connected to the RS-422 (+) input will be detected as a
logic high or low relative to the (-) input.
•
The TTL shaft encoder ground, the bias voltage ground, and the Xcelera-HS PX8 computer
system ground must be connected together.
RS-422 (-) Input Bias Source Generation
330
220
+5V
+2V
680
100
+12V
+1.5V
+1.5V
Battery
2.2K
150
+24V
+1.5V
Examples on Generating a DC voltage for the RS-422 (-) Input
Figure 41: Generating a DC Bias Voltage
•
DC voltage for the RS-422 (-) input can be generated by a resister voltage divider.
•
Use a single battery cell if this is more suitable to your system.
•
A DC voltage (5 or +12) is available on External Signals Connector J1 and J4.