Technical Specifications
X64 Xcelera-HS PX8 User's Manual
•
Opto-coupler response time is 0.8
µ
s for a rising signal.
•
Opto-coupler response time is 1.7
µ
s for a falling signal.
•
See
Line Trigger Source Selection for Linescan Applications
" on page 42
for more information.
•
Refer to Sapera parameters:
CORACQ_PRM_SHAFT_ENCODER_ENABLE CORACQ_PRM_SHAFT_ENCODER_DROP
or refer to CORACQ_PRM_EXT_LINE_TRIGGER_ENABLE
CORACQ_PRM_EXT_LINE_TRIGGER_DETECTION
CORACQ_PRM_EXT_LINE_TRIGGER_LEVEL (fixed at RS-422)
CORACQ_PRM_EXT_LINE_TRIGGER_SOURCE
CORACQ_PRM_SHAFT_ENCODER_SOURCE
•
See also *.cvi file entries:
Shaft Encoder Enable, Shaft Encoder Pulse Drop
or see External Line Trigger Enable, External Line Trigger Detection, External Line Trigger Level,
External Line Trigger Source.
Note 5: Strobe Output Specifications
One TTL Strobe output is provided. The following figure is typical for the strobe out.
FB
Strobe
Strobe EN
Figure 36: Strobe Output Electrical Diagram
•
Each strobe output is a tri-state driver, enabled by software.
•
Each strobe output is 5V TTL level.
•
Each output has a ferrite bead.
•
Maximum source current is 32mA typical.
•
Maximum sink current is 32mA typical.
•
Output switching is < 4.2ns typical.
•
Refer to Sapera Strobe Methods parameters:
CORACQ_PRM_STROBE_ENABLE
CORACQ_PRM_STROBE_POLARITY
CORACQ_PRM_STROBE_LEVEL
CORACQ_PRM_STROBE_METHOD
CORACQ_PRM_STROBE_DELAY
CORACQ_PRM_STROBE_DURATION
•
See also *.cvi file entries:
Strobe Enable, Strobe Polarity, Strobe Level, Strobe Method, Strobe Delay, Strobe Duration.
Note 6: DC Power Details for J7
Warning: Never remove or install any hardware component with the computer
power on. Never connect a floppy drive power cable to J7 when the computer is
powered on.
•
Connect the PC floppy drive power connector to J7 so as to supply DC power to the External
Signal connectors. Both 5Vdc and 12Vdc are available on J1 or on the DB37 External Signals
Bracket Assembly.
•
Both the 5Volt and 12Volt power pins have a 1.5 amp re-settable fuse on the board. If the fuse
is tripped, turn off the host computer power. When the computer is turned on again, the fuse is