70
Spyder3 GigE Vision SG-14 Monochrome Cameras User’s Manual
03-032-20123-01
Teledyne DALSA
Figure 52: Frame Trigger Delayer
External Frame Trigger – Frame Active Trigger mode.
In the Start Mod e grou p > Make su re Fram e Start Trigger Mod e is Off.
Figure 53: Frame Start Trigger Mode: Off
In the Fram e Trigger Fu nction Grou p > Set the Device Scan typ e to Areascan.
Figure 54: Frame Trigger Source
In the Active Mod e grou p > set the Fram e Active Trigger Mod e valu e to ON .
Figure 55: Frame Trigger Mode: On