92
•
Technical Specifications
Xtium2-CL MX4 User's Manual
Serial Port
Supports communication speeds from 9600 to 921600 bps
Controls
Compliant with Teledyne DALSA Trigger-to-Image Reliability framework
Comprehensive event notifications
Timing control logic for camera triggers and strobe signals
External trigger latency less than 100 nsec
Supports multi-board / multi-camera synchronization
Quadrature (phase A & B) shaft encoder inputs for external web
synchronization: RS-422 or TTL input (mutually exclusive) maximum
frequency is 5 MHz
4 differential opto-coupled general inputs (RS-422/TTL/12V/24V).
Can be used as opto-coupled external trigger inputs programmable as
active high or low (edge or level trigger).
9 LVTTL general outputs. Can be used as Strobe outputs.
I/O available on a DH60-27P connector (J5), 26-pin SHF-113-01-L-D-RA
(J1) and 40-pin TST-120-01-G-D (J2)
PoCL
Overcurrent circuit protection:
PTC (Positive Temperature Coefficient):
2 on the board, one each for the 2 PoCL circuits.
PTCs are limited to 0.5A (hold) and 1A (trip) @ 25C.
Part used is Littelfuse’s 1210L050.
Processing
Dependent on user
loaded firmware
configuration
Output Lookup Table
Bayer Mosaic Filter
Bi-Color Conversion (for TDALSA P4)
Flat Field/Flat Line Correction
3x3 Image Filter (Convolution)
Certifications
EC & FCC Class A (see Declarations of Conformity)
CE, KC, UKCA
RoHs (Restriction of Hazardous Substances)
REACH (Registration, Evalulation Authorization and Restriction of
Chemicals)
China RoHS2
UL94 (Standard for Safety of Flammability) (PCB only)