Xtium2-CL MX4 User's Manual
Technical Specifications
•
93
Host System Requirements
Xtium2-CL MX4 Dimensions
Approximately 6.5 in. (14 cm) wide by 4 in. (10 cm) high
General System Requirements for the Xtium2-CL MX4
•
PCI Express Gen3 x4 slot compatible;
(will work in Gen1 or Gen 2 x4 slot with reduced bandwidth to host)
•
On some computers the Xtium2-CL MX4 may function installed in a x16 slot. The computer
documentation or direct testing by the user is required.
•
Xtium2-CL MX4 operates correctly when installed in a multi-processor system (including
Hyper-Threading multi-core processors).
Operating System Support
Windows 7, Windows 8 and Windows 10, each in either 32-bit or 64-bit
Environment
Ambient Temperature:
10° to 50°C (operation)
-40° to 75°C (storage)
Relative Humidity:
5% to 90% non-condensing (operating)
0% to 95% (storage)
MTBF @40°C
83 years
Note:
Ensure adequate airflow for proper functioning of the board across the entire
temperature range of 10
–
50°C . Airflow measuring 20 LFM (linear feet per minute)
across the surface of the board is recommended.
Power Requirements during Acquisitions
PC Voltage
Power Consumed
+3.3V
4.7 W
+12V
4.5 W