40
•
CamExpert Quick Start
Xtium2-CL MX4 User's Manual
Advanced Control Category
The Advanced Control category groups parameters for configuring camera control signals, board
sync outputs and other advanced settings.
Parameter Descriptions
The following table describes the CamExpert Advanced Control category of Sapera LT parameters.
Acquisition server notes, if applicable, indicate if parameter availablility or supported values are
dependent on the selected frame grabber acquisition server and acquisition device.
Display
Name
Parameter
Description
Notes
Internal Frame
Trigger
CORACQ_PRM_INT_FRAME_TRIGGER_ENABLE
Enables/disables the acquisi
tion device’s
internal frame trigger. Boolean parameter
(TRUE or FALSE).
Applies to
areascan cameras
only.
Internal Frame
Trigger Frequency
(in Hz)
CORACQ_PRM_INT_FRAME_TRIGGER_FREQ
Internal frame trigger frequency in Hz. Set
to the required frame rate when using
internal frame trigger to control camera
acquisition. Valid range is 0.001-10000Hz.
Line Sync Source
CORACQ_PRM_EXT_LINE_TRIGGER_ENABLE
CORACQ_PRM_INT_LINE_TRIGGER_ENABLE
CORACQ_PRM_SHAFT_ENCODER_ENABLE
Selects the line trigger source for linescan
cameras, unless free-running.
Applies to linescan
cameras only.
Interal Line
Trigger Frequency
(in Hz)
CORACQ_PRM_INT_LINE_TRIGGER_FREQ
Sets the internal line trigger frequency, in
Hz. Applies only when the Line Sync Source
is set to Internal Line Trigger.
Applies to linescan
cameras only.
Camera Line
Trigger Frequency
Min (in Hz)
CORACQ_PRM_CAM_LINE_TRIGGER_FREQ_MIN
Sets the camera’s minimum line trigger
frequency. Minimum value is 1Hz.
Applies to linescan
cameras only.
Camera Line
Trigger Frequency
Max (in Hz)
CORACQ_PRM_CAM_LINE_TRIGGER_FREQ_MAX
Sets the camer
a’s maximum line trigger
frequency. Maximum value is 10000000 Hz.
Applies to linescan
cameras only.
Camera Control
method selected
CORACQ_PRM_TIME_INTEGRATE_ENABLE
CORACQ_PRM_LINE_TRIGGER_ENABLE
Enables or disables an available camera
control method. Each supported control
method has one or more operating modes
to choose from; refer to the parameters:
Camera Trigger Method Setting
Time Integration Method Setting.