Preserving Board Parameters during Board
Replacement or System Cloning
When replacing a board in a system or cloning a system configuration using a harddrive im age, if
the previous device parameter settings differ from the factory default driver settings it is indicated
as “User Defined” or “Manual Configuration” in the Teledyne DALSA Device Manager start
-up dialog
under the Device Info column. User-defined settings are specific to the PCI Express slot on the
system.
Figure 6: Firmware Update Status
To preserve the user defined parameter settings, select “
Manual
” and proceed with the update;
differences between the current settings are shown in green in both the Device Info and Device
Update tabs.
For systems with mulitple boards, if boards use different firmware configurations, disable the
Same Firmware For All Devices
option (otherwise the configuration specified for the first board
according to slot position is applied to all boards in the system).