PIM00413
13-5
Warning
Code
Name Reason
Countermeasures
Motor cooling fan is stopped
・
Replace the fuse for motor
cooling fan
・
Replace the motor cooling fan
・
Replace the controller
Radiator is clogged
・
Replace or clean the radiator
Rotation speed of the motor is
rising
・
Check the leakage amount in
the main unit side circuit
・
Check the setting of the high-
pressure safety valve
・
Replace the motor pump
L44
Motor temperature
abnormal warning
Motor temperature exceeded
the specified value 83
℃
for
10 seconds or more
The ambient temperature is
high
・
Install it in the place where the
ambient temperature is within
the required range
・
Install in well-ventilated place
The cooling fan for controller
is stopped
・
Replace the fuse for cooling
fan
・
Replace the cooling fan
・
Replace the controller
Radiator is clogged
・
Replace or clean the radiator
L45
Fin temperature abnormal
warning
Fin temperature exceeded the
specified value 73
℃
for 10
seconds or more
Rotation speed of the motor is
rising
・
Check the leakage amount in
the main unit side circuit
・
Check the setting of the high-
pressure safety valve
・
Replace the motor pump
The power supply voltage is
low
・
Check the power supply voltage
in monitor mode [n12: main
circuit voltage], and make it in
the required range
L50
Power supply voltage drop
warning
Main circuit DC voltage is
below the specified
value:DC430V(Power supply
voltage convertion
AC304V)-2 sec.
Failure of the controller
・
Replace the controller
The power supply voltage is
low
・
Check the power supply voltage
in monitor mode [n12: main
circuit voltage], and make it in
the required range
Pump failure
・
Replace the motor pump
L60
Pressure deviation
abnormal warning
Current command is
saturated
Encoder phase is shifted by
noise (no F)
・
Add a noise filter
Setting mistake of pressure
switch setting value
・
Check the pressure switch
setting value
L62
Pressure drop warning
Pressure switch is activated
for 30 seconds or more
consecutive.
Oil leakage from main engine
・
Improve the oil leakage in
main unit side
L63
Pressure switch activation
Pressure switch is activated
Pressure becomes less than the
setting value of the parameter
"P01: Pressure switch"
・
If there is no abnormality in
main machine, please review
the parameter settings for the
pressure switch.
Please refer to
the "12.5 Pressure switch
setting" for more information.
Содержание SUT06S3016-30
Страница 2: ......
Страница 12: ......
Страница 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30...
Страница 21: ...PIM00413 3 7 SUT00S6007 30...
Страница 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension...
Страница 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30...
Страница 24: ...PIM00413 3 10 SUT06S6007 30...
Страница 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2...
Страница 26: ...PIM00413 3 12 SUT10D6021 30...
Страница 36: ......
Страница 38: ......
Страница 42: ......
Страница 54: ......
Страница 64: ......