PIM00413
8-3
■
Unit Type (SUT06, SUT10)
There are different port types below for unit types. Please be sure to pipe the outlet port and return port. The
details of the pipe position is separately described in the form drawing. Hose piping and seal taping are required
when piping.
●
Unit Type (SUT06, SUT10) Porting Specifications
Product type
Pipe port
Pipe size
Recommended hose pressure
Default
Outlet port
Rc 3/8
20.5MPa
Vinyl cap
Drain port
Rp 3/4
1.5MPa
Vinyl cap
Option port
Rp 3/8, Rp 1/2
1.5MPa
Square head plug
Return port
Rc 1
1.5MPa
Vinyl cap
SUT06S3016-30
Return port
Rc 3/4
1.5MPa
Hexagon socket
head plug
Outlet port
Rc 3/4
SUT06S6007-30:10.5MPa
SUT06D4016-30:20.5MPa
SUT06D6021-30:34.5MPa
SUT10D6021-30:34.5MPa
Vinyl cap
Drain port
Rp 3/4
1.5MPa
Vinyl cap
Option port
Rp 3/8, Rp 1/2
1.5MPa
Square head plug
Return port
Rc 1
1.5MPa
Vinyl cap
SUT06S6007-30
SUT06D4016-30
SUT06D6021-30
SUT10D6021-30
Return port
Rc 3/4
1.5MPa
Hexagon socket
head plug
Outlet port
Rc 3/4
Return port
Rc 1
Option port
Rp 3/8
Drain port
Rp 3/4
Return port
Rc 3/4
Outlet port
Rc 3/8
SUT06S3016-30
Option port
Rp 1/2
CAUTION
●
Please use hose to pipe.
●
When piping the hose, the bending radius of the hose should be more than its specification value.
●
Please do not twist the hose.
●
Please support the hose if there is a excessive distortion due to the weight of the hose.
Содержание SUT06S3016-30
Страница 2: ......
Страница 12: ......
Страница 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30...
Страница 21: ...PIM00413 3 7 SUT00S6007 30...
Страница 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension...
Страница 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30...
Страница 24: ...PIM00413 3 10 SUT06S6007 30...
Страница 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2...
Страница 26: ...PIM00413 3 12 SUT10D6021 30...
Страница 36: ......
Страница 38: ......
Страница 42: ......
Страница 54: ......
Страница 64: ......