PIM00413
11-9
④
Press any key among
,
,
to go back to the alarm history number.
No. Panel display
Representation
Unit
Remarks
1 A*A
Alarm
Content -
Alarm
Content
2 A*b Power
on
times times
The number of Power on times when an alarm
occurs
3 A*S Rotational
speed
10min
-1
Motor speed at the time of alarm
4 A*n
PQ number and
pump state
-
PQ number and pump state at the time of alarm
occurrence.
example) “L02” PQ No. 2, single pump
5 A*q
Current
value Ampere
Current when the alarm occurs
6 A*V
Main circuit DC
voltage
V
Main circuit DC voltage when the alarm occurs
* is the number of 0-9, representing the alarm history.
Note
・
If the power-ON times exceeds 999 times, it will be cleared to 0.
・
If the value of rotation speed is
minus
when the alarm occurs
,
three dots will light up.