FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
Split Sensira R32
ESIE18-12E – 2021.02
RXF50A
a
b
c
d
e
e
f
g
h
M1C
R1T
R2T
R3T
Y1E
Y1S
e
e
i
j
M1F
a
Field piping (liquid: Ø6.4 mm flare connection)
b
Field piping (gas: Ø12.7 mm flare connection)
c
Stop valve (liquid)
d
Stop valve (gas)
e
Muffler
f
Liquid receiver
g
Filter
h
Muffler with filter
i
Heat exchanger
j
Accumulator
M1C
Compressor
M1F
Fan
R1T
Thermistor (outdoor air)
R2T
Thermistor (heat exchanger)
R3T
Thermistor (compressor discharge)
Y1E
Electronic expansion valve
Y1S
Solenoid valve (4‑way valve)
Cooling
Heating
INFORMATION
The diagrams shown in this manual may be incorrect due to changes/updates to the
unit. Correct diagrams are supplied with the unit and can also be found in the
technical data book.