5
|
Technical data
Service manual
158
FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
Split Sensira R32
ESIE18-12E – 2021.02
A RXF50B
a
b
c
d
f
h
M1C
R1T
R2T
R3T
Y1E
Y1S
e
e
i
j
S1PH
M1F
g
e
e
e
a
Field piping (liquid: Ø6.4 mm flare connection)
b
Field piping (gas: Ø12.7 mm flare connection)
c
Stop valve (liquid)
d
Stop valve (gas)
e
Muffler
f
Liquid receiver
g
Filter
h
Muffler with filter
j
Heat exchanger
j
Accumulator
M1C
Compressor
M1F
Fan
R1T
Thermistor (outdoor air)
R2T
Thermistor (heat exchanger)
R3T
Thermistor (discharge pipe)
S1PH
High pressure switch
Y1E
Electronic expansion valve
Y1S
Solenoid valve (4‑way valve)
Heating
Cooling
INFORMATION
The diagrams shown in this manual may be incorrect due to changes/updates to the
unit. Correct diagrams are supplied with the unit and can also be found in the
technical data book.
Содержание Sensira Series
Страница 169: ......
Страница 170: ......
Страница 171: ......
Страница 172: ...ESIE18 12E 2021 02 Copyright 2018 Daikin Verantwortung f r Energie und Umwelt...