2
|
Components
Service manual
43
FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
Split Sensira R32
ESIE18-12E – 2021.02
c
d
a
b
a
a
4‑way valve pipe
b
4‑way valve
c
Putty
d
Insulation
6
Install the putty (if available) and the insulation (if available) in their original
location.
7
Install the 4‑way valve coil on the 4‑way valve body, see
8
Add
refrigerant
to
the
refrigerant
circuit,
see
133].
To install the 4-way valve coil
1
Install the 4‑way valve coil on the 4‑way valve body.
c
a
b
a
Screw
b
4‑way valve coil
c
4‑way valve body
2
Install and tighten the screw to fix the 4‑way valve coil.
3
Route the 4‑way valve coil harness towards the appropriate PCB.
4
Connect the 4‑way valve coil connector to the PCB.
WARNING
When reconnecting a connector to the PCB, make sure to connect it on the correct
location and do NOT apply force, as this may damage the connector or connector
pins of the PCB.
5
Fix the 4‑way valve coil harness using new tie straps.
Is the problem solved?
Action
Yes
No further actions required.
Содержание Sensira Series
Страница 169: ......
Страница 170: ......
Страница 171: ......
Страница 172: ...ESIE18 12E 2021 02 Copyright 2018 Daikin Verantwortung f r Energie und Umwelt...