5
|
Technical data
Service manual
155
FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
Split Sensira R32
ESIE18-12E – 2021.02
5.3.2 Piping diagram: Outdoor unit
RXF20+25A + RXF20+25B + RXF20~35C + 25A + ARXF20~35C
a
b
c
d
e
f
g
h
M1C
R1T
R2T
R3T
Y1S
M1F
e
Y1E
S1PH
a
Field piping (liquid: Ø6.4 mm flare connection)
b
Field piping (gas: Ø9.5 mm flare connection)
c
Stop valve (liquid)
d
Stop valve with service port (gas)
e
Muffler with filter
f
Heat exchanger
g
Accumulator
h
Muffler
M1C
Compressor
M1F
Fan
R1T
Thermistor (outdoor air)
R2T
Thermistor (heat exchanger)
R3T
Thermistor (compressor discharge)
Y1E
Electronic expansion valve
Y1S
Solenoid valve (4‑way valve)
S1PH
High pressure switch
Cooling
Heating
INFORMATION
The diagrams shown in this manual may be incorrect due to changes/updates to the
unit. Correct diagrams are supplied with the unit and can also be found in the
technical data book.
Содержание Sensira Series
Страница 169: ......
Страница 170: ......
Страница 171: ......
Страница 172: ...ESIE18 12E 2021 02 Copyright 2018 Daikin Verantwortung f r Energie und Umwelt...