2
|
Components
Service manual
114
FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
Split Sensira R32
ESIE18-12E – 2021.02
2.11.2 Repair procedures
For class 20~42 units
See procedures below.
For class 50~71 units
As the reactors are part of the main PCB, replace the complete main PCB. See
To remove the reactor
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
1
Remove the required plate work, see
101].
2
Remove the Faston connectors to disconnect the wires from the reactor.
3
Remove the 2 screws that fix the reactor to the switch box.
4
Remove the reactor.
a
b
b
a
Reactor
b
Screw
5
To install the reactor
1
Install the reactor on the correct location on the switch box.
a
b
b
a
Reactor
b
Screw
2
Install the 2 screws that fix the reactor to the switch box.
3
Connect the Faston connectors to the reactor.
Is the problem solved?
Action
Yes
No further actions required.