IM 1287-4 • REBEL APPLIED ROOFTOP 158 www.DaikinApplied.com
Rooftop Equipment Warranty Registration Form
Rebel Applied Equipment Warranty Registration Form
Select Yes or No. If not applicable to the type of unit, select N/A.
13F-41577
6
. .
. .
VIII.
FURNACE CHECK, TEST, & START
A.
Gas Furnace ……………………………………………………………….Model no___________________ Serial no. ________________
B.
Gas pressure at main (inches w.c.): ...................................................................................................................................
C.
Gas pressure at manifold (inches w.c.): .............................................................................................................................
D. Flame failure shutoff (seconds): .........................................................................................................................................
Mod gas pressure
Min fire rate (20-1 & 100-1 is 5%, 10-1 is 10%, 5-1 is 20%) ……Manifold pressure___ in w.c CO _______ppm CO2 _____ppm
At 50% ……………… …………………………………………………Manifold pressure___ in w.c CO _______ppm CO2 _____ppm
At 100% …………………………………………………………………Manifold pressure___ in w.c CO _______ppm CO2 _____ppm
Gas Supply at 100% _______ In Wc
Staged gas manifold pressures
1
st
stage ……………………… _______ In wc CO _______ppm CO2 _____ppm Gas Supply pressure _______ In Wc
2
nd
stage ……………………… _______ In wc CO _______ppm CO2 _____ppm Gas Supply pressure _______ In Wc
3
rd
stage ……………………… _______ In wc CO _______ppm CO2 _____ppm Gas Supply pressure _______ In Wc
4th stage ……………………… _______ In wc CO _______ppm CO2 _____ppm Gas Supply pressure _______ In Wc
IX.
MAINTAINING MICROTECH CONTROL PARAMETER RECORDS
After the unit is checked, tested, and started and the final control parameters are set, Save the final settings by exporting the param.bin
and ucf files. Keep these records on file and update them whenever changes to the control parameters are made. Keeping a record
facilitates any required analysis and troubleshooting of the system operation and facilitates restoration after a controller replacement.
Thank you for completing this form. Please sign and date below.
Signature
Startup date:
Return completed form by mail to:
Daikin Warranty Department, 13600 Industrial Park Boulevard, Minneapolis, MN 55441
or by email to:
Please fill out the Daikin Applied “Quality Assurance Survey Report” and list any additional comments that could affect the operation of this unit; e.g., shipping damage, failed
components, adverse installation applications, etc. If additional comment space is needed, write the comment(s) on a separate sheet, attach it to the Survey Report and return it to
the Warranty Department of Daikin Applied with the completed Equipment Warranty Registration form.
E. Heat section turns off upon loss of airflow?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes
No
N/A
F. Main Gas Valves shut off Operational? . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G. Gas Heat Performance
Yes
No
N/A
Submit Form
Clear Form
Содержание Rebel Applied DPSA
Страница 15: ...Introduction www DaikinApplied com 15 IM 1287 4 REBEL APPLIED ROOFTOP Figure 17 VFD Inverter Box Components ...
Страница 109: ...Unit Maintenance www DaikinApplied com 109 IM 1287 4 REBEL APPLIED ROOFTOP Figure 159 10kW 50kW Full SCR Control ...
Страница 144: ...IM 1287 4 REBEL APPLIED ROOFTOP 144 www DaikinApplied com Furnace Wiring Diagrams Figure 178 600 MBH 2 Stage ...
Страница 145: ...Furnace Wiring Diagrams www DaikinApplied com 145 IM 1287 4 REBEL APPLIED ROOFTOP Figure 179 600 MBH 4 Stage ...
Страница 147: ...Figure 181 600 MBH 5 1 Modulation 400 MBH and 600 MBH 10 1 Modulation ...
Страница 160: ......
Страница 161: ......