background image

28

English

Maintenance

 WARNING

Be sure to stop operation and unplug the power supply plug before performing maintenance.

(An electric shock or injury may result)

How to remove the humidifying tray and humidifying filter unit

1. 

Remove the water tank. 

 

Page 15

2. 

Pull out the humidifying tray and remove 

humidifying filter unit.

Humidifying 

filter unit

Lift up slightly and pull out

Humidifying 
tray

Hold the outer 
periphery of the 
frame

•  If there is water inside, the water surface may shake 

and spill, so pull it out slowly.

•  Hold the bottom of the humidifying tray when carrying.

How to attach the humidifying tray and humidifying filter unit

1. 

Attach the humidifying tray and humidifying 

filter unit.

1

  Attach the humidifying filter unit

Fit axle into groove in humidifying tray

Humidifying 

filter unit

Groove

Axle

2

  Push the humidifying tray all the way in

• 

If the humidifying filter unit is not properly attached to 

the humidifying tray, the humidifying tray cannot be 
attached to the unit.

Attention

After attaching the humidifying tray to the unit, do not forcibly 

rotate the humidifying filter unit. Malfunction may result.

2. 

Install the water tank. 

 

Page 15

Humidifying tray 

Wash with water

Wash with water about 

1 time every 3 days, or if 

odor and dirt are still an 

issue. 

•  Use a soft cloth, brush, or 

cotton swab to clean hard-
to-reach places.

•  For areas with water scales, 

remove the water scales 
with a soft cloth or brush or 
cotton swab soaked in 
lukewarm or room 
temperature water in which 
citric acid has been 

dissolved. (Lift up the float 
and check that there are no water scales under the float)

 

Finally, rinse with water.

•  Citric acid may be purchased at a pharmacy or drug 

store.

Note

•  Depending on water quality and the usage 

environment, water in the humidifying tray may 
become discolored due to water scales etc. Clean it 
also in such cases.

• 

Make sure that the float is not stuck in water scales. 

 

(Water leakage may result if the float is stuck)

Attention

Float

• 

Do not remove.

Humidifying Operation 
will become impossible.

If the float is detached from the tray

Insert the axle into the 
hole of the tray
• 

Make sure the float is 

placed below the tray 
protrusion.

Tray protrusion

Sectional illustration

Float

• 

Pour water into the tray and check that the float rises.

•  After checking, be sure to discard the water, then 

attach the humidifying tray to the unit.

Discard the residual water 
in the tray from here 

Float

01_EN_3P672685-2A.indd   28

2021/12/13   13:56:05

Содержание MCKB70YSAU

Страница 1: ...fying air purifier Please read the operation manual carefully and follow it for correct use Please read the Safety Precautions section before use Please keep the operation manual in a safe place for l...

Страница 2: ...1...

Страница 3: ...t Particle Sensor Sensitivity Setting 21 Monitoring mode within AUTO Operation and ECONO MODE 21 Airflow rate range for AUTO FAN 21 Humidifying Filter Drying Operation 23 Airflow rate set to Quiet whe...

Страница 4: ...ced by the manufacturer its service agent or a similar qualified person in order to avoid a hazard Electric shock short circuit or fire may result from use while damage Do not operate this appliance w...

Страница 5: ...ely dispose of the packing materials Packing materials such as nails and other metal or wooden parts may cause cuts or other injuries Tear apart and throw away plastic packaging bags so that children...

Страница 6: ...During use Small children or immobile persons due to illness or injury should not operate the unit by themselves This appliance is not intended for use by persons including children with reduced physi...

Страница 7: ...ormalities Once a day fill the water tank with water Check that the water tank is clean and there is no water leaking from the tank If water leaks household items may get wet and electric shock and el...

Страница 8: ...to outdoor air e g near windows etc or direct airflow from air conditioners etc Room humidity may not be detected and indicated correctly Positions near combustion based heating devices and other high...

Страница 9: ...Dust Particle sensor Inside the air inlet right side Page 9 21 22 25 34 Air inlets Front Side UV unit Inside the unit Humidifying tray Grip is below Back Model name Production no Power supply plug Po...

Страница 10: ...tion filter needs to be replaced and blinks when it is time to replace the dust collection filter Operating Indicator panel Dust Particle sensor lamp Indicates the volume of dust in 3 colors blue oran...

Страница 11: ...heir meanings Page 33 Odor sensor lamp Indicates the intensity of odors in 3 colors blue orange red Blue indicates that the air is clean Blue Orange Red Low High Lamp color Odors If operation is start...

Страница 12: ...etting lamps white Indicate the humidity setting in 3 levels Low Standard High Humidifier lamp white Lights up during Humidifying Operation Slowly blinks during humidifying filter drying operation Pag...

Страница 13: ...TO operation Page 16 AUTO button Optimum operation will be performed according to the condition of the room Page 16 ON OFF button Press to turn the power ON press again to turn OFF After operation sto...

Страница 14: ...noise from nearby radios or stereos move the unit to at least 7ft 2m away from the device Keep cordless phones and radio controlled clocks away from the unit also Attention To avoid staining of walls...

Страница 15: ...nk When starting operation if a notification tone sounds and the odor sensor lamp blinks the carbon filter and the filter fixing unit are not properly installed Re install the carbon filter and the fi...

Страница 16: ...er tank with tap water Perform in a place where spilling water will not cause a problem Clean the water tank by shaking a small amount of water inside before filling up the water tank with water For m...

Страница 17: ...er Low Standard or High Monitoring mode Blinking About AUTO operation The unit automatically switches between Air Purifying Operation and Humidifying Operation based on the indoor temperature and humi...

Страница 18: ...e the unit is set to carry out Air Purifying Operation in AUTO FAN MODE If the power supply plug is unplugged or the unit is stopped and started again the operation that was in progress last time will...

Страница 19: ...a rough estimate Standard Operation is carried out automatically with a humidity of 50 as a rough estimate High Operation is carried out automatically with a humidity of 60 as a rough estimate Dependi...

Страница 20: ...of UV rays the emission of UV rays stops and the UV ON OFF lamp is turned off The UV emission is repeated approx 30 minutes every 90 minutes approx after the UV emission is stopped The setting return...

Страница 21: ...drawn in while the fan is stopped the sensitivity of the dust particle sensor odor sensor and humidity sensor will decrease If you do not want the sensitivity of the sensors to be reduced set Monitor...

Страница 22: ...med Operation can be performed either during operation or while operation is stopped Press for about 5 seconds and when a short beep sounds press while continuing to hold down When a short beep sounds...

Страница 23: ...hange the setting Each press cycles between ON and OFF Lit up ON Unlit OFF Press A short beep sounds the Humidity setting lamps Low blinks and the ECONO MODE lamp changes to the following display acco...

Страница 24: ...ws Blinking Lit up ON Unlit OFF Airflow rate set to Quiet when water supply lamp is lit ON OFF Setting at the time of purchase ON If you do not want the airflow rate set to Quiet when the water supply...

Страница 25: ...mode The settings will be remembered even if the power supply plug is removed Press to change the setting Each press cycles between ON and OFF Lit up ON Unlit OFF Press A short beep sounds the water...

Страница 26: ...emoving any dust using a vacuum cleaner remove and wash the filter with water then dry thoroughly in the shade Use a soft brush to clean the spaces between the slats Attention Do not use a cotton swab...

Страница 27: ...ixing unit is removed After maintenance be sure to attach the filter fixing unit again before operating Carbon filter For details on removal and attachment refer to Page 13 14 Cannot be washed with wa...

Страница 28: ...r a while about 30 seconds and check that there is no water leakage from the bottom of the tank Water leakage may result if dust is caught The inside of the water tank can be cleaned by removing the l...

Страница 29: ...lfunction may result 2 Install the water tank Page 15 Humidifying tray Wash with water Wash with water about 1 time every 3 days or if odor and dirt are still an issue Use a soft cloth brush or cotton...

Страница 30: ...results it is not a problem for use The parts can be used even if still wet after cleaning If not to be used for a prolonged period leave the parts in a shaded area to dry off thoroughly then attach...

Страница 31: ...g filter Water leakage may result if not correctly attached Securely slide it under filter retainers 6 places Protrusions 6 places The illustration shows the frame lower half Combination of frame and...

Страница 32: ...lamp will turn off About purchase and disposal Refer to Replacement Parts Page 40 Note The replacement timing of the dust collection filter depends on how it is used and the usage environment 1 Remov...

Страница 33: ...tic bag or similar to prevent dust entry and store the unit upright in a dry place Malfunction may result from storing the unit upside down or horizontally When not using Humidifying Operation off sea...

Страница 34: ...midifying tray and water tank attached Lamps may blink when the components are removed and the unit is operated If all components are attached An electrical component is malfunctioning Contact your de...

Страница 35: ...hed with water Do I need to replace it A It cannot be washed with water If you wash it with water it will lose its shape and you will not be able to use it If you inadvertently washed it with water re...

Страница 36: ...ashing on the humidifying filters Whistling and fluttering sound during operation Is there a buildup of dust on the pre filter Clean it Page 25 Is the dust collection filter clogged up Depending on us...

Страница 37: ...Page 10 If you remove the power supply plug when the air is clean odor free wait at least 5 seconds then reinsert the power supply plug and start operation the reference odor level that determines the...

Страница 38: ...customer service center The airflow rate cannot be adjusted Is the odor sensor lamp blinking Attach the carbon filter and filter fixing unit properly Page 14 Humidifying function Phenomenon Check poi...

Страница 39: ...but Humidifying Operation does not stop the humidifying filter unit continues to rotate Even if the water supply lamp lights up the humidifying filter unit will continue to rotate for about 90 minute...

Страница 40: ...ed Is humidifying filter drying operation set to OFF Page 23 24 There is water spilled on the floor Have you tilted the unit If you tilt the unit water may spill out Before moving the unit turn off th...

Страница 41: ...n the water tank is filled while installed in the unit If the water tank is removed from the unit before filling the water tank volume is 0 66 gallons 2 5 liters in order to make carrying easier Repla...

Страница 42: ...TE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection again...

Отзывы: