SiMT041311E
Operation Manual
Installation / Operation Manual
88
14
Mode
Mode
AUTO
Circulation
BREEZE
Mode
CAUTION
Notes on airflow rate
• When the airflow rate setting is “AUTO”, starting COOLING, “SARARA” DRY, or DRY COOLING operation (including the operation
selected with “AUTO”) triggers the deodorising function which reduces odour coming from the indoor unit and the unit does not blow air
immediately. Wait for about 40 seconds. (SMELL PROOF)
• When the airflow rate is lowered, the flaps and louvres will stop. When the vertical airflow direction is set to “Swinging”, the flaps stop in
an upward direction.
• At smaller airflow rates, the cooling/heating effect is also smaller.
< Airflow rate settings in each operation mode >
“SARARA” DRY / DRY COOLING
AUTO / COOLING / HEATING / “URURU” HUMIDIFY / HUMID HEATING* / FAN ONLY
Airflow rate setting
AUTO
AUTO, Indoor unit quiet, Airflow rate 1-5
* When the humidity is set to “MOISTURISING”, the airflow rate becomes “AUTO”.
Notes on vertical airflow direction
“AUTO”, “Circulation” and “BREEZE” airflow can be set according to the operation mode.
Circulation airflow
This setting blows air far using the space of the
ceiling. Moreover, air can be circulated in the whole
room by taking air from the shutter (bottom air inlet),
to eliminate the temperature variation.
BREEZE airflow
This setting automatically adjusts the airflow rate and
vertical airflow direction to generate a breeze-like
airflow. It is a comfortable airflow even when it blows
on your body.
Airflow direction setting
< Settings of “AUTO”, “Circulation”, and “BREEZE” airflow in each operation mode >
AUTO
COOLING / “SARARA” DRY / DRY COOLING
HEATING / “URURU” HUMIDIFY / HUMID HEATING
FAN ONLY
< Settings of “AUTO” airflow in each operation mode >
Airflow direction setting
COOLING / DRY COOLING
HEATING / HUMID HEATING
“SARARA” DRY
“URURU” HUMIDIFY
Circulation airflow BREEZE airflow
Downward air blowing and circulation airflow are repeated.
When the indoor temperature is a little lower
When the indoor temperature is a little higher
Circulation
Circulation airflow
BREEZE airflow
< Movable range of the flaps >
The movable range of the flaps varies according to the operation mode.
COOLING / “SARARA” DRY /
DRY COOLING
HEATING /
“URURU” HUMIDIFY /
HUMID HEATING
FAN ONLY
• Always use a remote controller to adjust the angles of the flaps and louvres. If you attempt to move the flaps and louvres forcibly by
hand when they are swinging, the mechanism may be damaged.
• Always use a remote controller to adjust the louvres angles. Inside the air outlet, a fan is rotating at a high speed.