Main Functions
SiMT041311E
43
Function and Control
1.20 Other Functions
1.20.1 Hot-Start Function
In order to prevent the cold air blast that normally occurs when heating operation is started, the
temperature of the indoor heat exchanger is detected, and the airflow is either stopped or
significantly weakened resulting in comfortable heating.
Note:
The cold air blast is prevented using similar control when defrost control starts or when the
thermostat is turned ON.
1.20.2 Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal
receiving sound.
1.20.3 Indoor Unit ON/OFF Button
An ON/OFF button is provided on the display of the unit.
Press this button once to start operation. Press once again to stop it.
This button is useful when the remote controller is missing or the battery has run out.
The operation mode refers to the following table.
<Forced cooling operation>
Forced cooling operation can be started by pressing the ON/OFF button for 5 ~ 9 seconds while
the unit is not operating.
Refer to page 192 for detail.
Note:
When the ON/OFF button is pressed for 10 seconds or more, the forced cooling operation is
stopped.
1.20.4 Auto-restart Function
Even if a power failure (including one for just a moment) occurs during the operation, the
operation restarts automatically when the power is restored in the same condition as before the
power failure.
Note:
It takes 3 minutes to restart the operation because the 3-minute standby function is activated.
Mode
Temperature setting
Airflow rate
AUTO
25ºC
Automatic
ON/OFF button
(R19719)