Troubleshooting
SiMT041311E
141
Service Diagnosis
2.14 Humidity Sensor (for Room) Abnormality
Error Code
CC
Method of Error
Detection
Sensor abnormality is detected by input value.
Error Decision
Conditions
The input from the humidity sensor is 4.96 V and more or 0.04 V and less.
Supposed
Causes
Disconnection of connector
Defective humidity sensor
Defective indoor unit PCB (A1P, A4P)
Troubleshooting
Check No.07
Refer to P.182
Correct the connection.
Replace the humidity
sensor PCB (A4P).
Replace the control PCB
(A1P).
Normal?
(R19683)
Caution
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Check the connection of
connectors.
Normal?
NO
NO
YES
YES
Check No. 07
Check the input voltage of
humidity sensor.
* Connect the connector again for
ensuring the connection.