Operation Manual
SiMT041311E
107
Installation / Operation Manual
33
5
On *
Off
6
*
< Note >
< Setting guides >
7
< Note >
8
< Note >
• This function sets the volume of the receiving tone of the indoor unit.
To change the default settings
• When the indoor temperature or humidity falls far below the preset value, the fans of indoor and outdoor units are stopped
to keep the room comfortable.
This operation is activated in the COOLING, “SARARA” DRY, and DRY COOLING operations.
• When the CONTINUE DRY is set to “On”, starting the COOLING, “SARARA” DRY, or DRY COOLING operation triggers
the deodorising function which reduces any unpleasant odour coming from the indoor unit and the unit does not blow air for
40 seconds.
• Before the outdoor unit operates, the indoor temperature may be higher than the set temperature.
< Note >
CONTINUE DRY operation is performed.
CONTINUE DRY operation is not performed.
Description
Setting
Menu
No.
• Airflow direction is properly controlled by inputting data on the room shape and installation position of the indoor unit in the remote
controller. Set oblong or horizontal according to the room shape.
• If you do not set the right corner and left corner correctly, the airflow direction may not be properly controlled in some airflow settings.
• The airflow direction range at the horizontal airflow setting (airflow direction that can be selected with ) will change according
to the settings for the installation position.
When the distance is 2 to
50cm, set to the left corner.
When the unit is installed in
the centre, set to centre.
CONTINUE
DRY
When the distance is 2 to
50cm, set to the right corner.
Oblong centre *
The horizontal airflow direction blows air evenly to the right and left.
Oblong right corner
The horizontal airflow direction blows air to the left.
Oblong left corner
The horizontal airflow direction blows air to the right.
Horizontal centre
The horizontal airflow direction blows air evenly to the right and left.
Horizontal right corner
The horizontal airflow direction blows air to the left.
Horizontal left corner
The horizontal airflow direction blows air to the right.
INSTALLED
POSITION
Resets the total power consumption to 0kWh.
• This function resets the total power consumption.
• To check the power consumption, press .
* Default setting
RESET USED
POWER
SOUND
VOLUME
Reset with
APPLY
The volume is high.
Normal volume.
The volume is off.
High
Low *
Off