SiBE12-713
List of Functions
List of Functions
3
Category
Functions
F
T
KS20-35CAVMB
F
T
KS50-71FV1B
Category
Functions
F
T
KS20-35CAVMB
F
T
KS50-71FV1B
Basic
Function
Inverter (with Inverter Power Control)
{
{
Health &
Clean
Air Purifying Filter
—
—
Operation Limit for Cooling (°CDB)
—
—
Operation Limit for Heating (°CWB)
—
—
Photocatalytic Deodorizing Filter
—
—
PAM Control
—
—
Air Purifying Filter with Photocatalytic
Deodorizing Function
{
—
Compressor
Oval Scroll Compressor
—
—
Titanium Apatite Photocatalytic
Air-Purifying Filter
—
{
Swing Compressor
—
—
Longlife Filter (Option)
—
—
Rotary Compressor
—
—
Mold Proof Air Filter
{
{
Reluctance DC Motor
—
—
Wipe-clean Flat Panel
{
{
Comfortable
Airflow
Power-Airflow Flap
—
—
Washable Grille
—
—
Power-Airflow Dual Flaps
{
{
Filter Cleaning Indicator
—
—
Power-Airflow Diffuser
—
—
Mold Proof Operation
—
—
Wide-Angle Louvers
{
{
Heating Dry Operation
—
—
Vertical Auto-Swing (Up and Down)
{
{
Good-Sleep Cooling Operation
—
—
Horizontal Auto-Swing (Right and Left)
—
{
Timer
Weekly Timer
—
—
3-D Airflow
—
{
24-Hour On/Off Timer
{
{
Comfort Airflow Mode
—
—
72-Hour On/Off Timer
—
—
3-Step Airflow (H/P Only)
—
—
Night Set Mode
{
{
Comfort
Control
Auto Fan Speed
{
{
Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
{
{
Indoor Unit Quiet Operation
{
{
Self-Diagnosis (Digital, LED) Display
{
{
Night Quiet Mode (Automatic)
—
—
Wiring Error Check
—
—
Outdoor Unit Quiet Operation (Manual)
—
—
Anticorrosion Treatment of Outdoor
Heat Exchanger
—
—
Intelligent Eye
{
{
Quick Warming Function
—
—
Flexibility
Multi-Split / Split Type Compatible
Indoor Unit
{
{
Hot-Start Function
—
—
Automatic Defrosting
—
—
Flexible Voltage Correspondence
{
—
Operation
Automatic Operation
—
—
High Ceiling Application
—
—
Programme Dry Function
{
{
Chargeless
—
—
Fan Only
{
{
Either side Drain (Right or Left)
{
{
Lifestyle
Convenience
New Powerful Operation (Non-
Inverter)
—
—
Power Selection
—
—
Inverter Powerful Operation
{
{
Remote
Control
5-Rooms Centralized Controller
(Option)
{
{
Priority-Room Setting
—
—
Remote Control Adaptor
(Normal Open-Pulse Contact) (Option)
{
{
Cooling / Heating Mode Lock
—
—
Home Leave Operation
{
{
Remote Control Adaptor
(Normal Open Contact) (Option)
{
{
ECONO Mode
—
—
Indoor Unit On/Off Switch
{
{
DIII-NET Compatible (Adaptor)
(Option)
{
{
Signal Reception Indicator
{
{
Remote
Controller
Wireless
{
{
Temperature Display
—
—
Wired
—
—
Another Room Operation
—
—
Note:
{
: Holding Functions
— : No Functions
Содержание F-Series
Страница 1: ... Applied Models Inverter Multi Cooling Only Inverter Multi Heat Pump F Series SiBE12 713 ...
Страница 11: ...Introduction SiBE12 713 x ...
Страница 47: ...Specifications SiBE12 713 36 Specifications ...
Страница 113: ...Control Specification SiBE12 713 102 Function and Control ...
Страница 122: ...SiBE12 713 Instruction Operation Manual 111 FTK X S 20 25 35 C Names of parts Indoor Unit ...
Страница 235: ...Instruction SiBE12 713 224 Operation Manual ...
Страница 297: ...Check SiBE12 713 286 Service Diagnosis ...
Страница 316: ...SiBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points ...
Страница 330: ...SiBE12 713 Others 319 Part 8 Others 1 Others 320 1 1 Test Run from the Remote Controller 320 1 2 Jumper Settings 321 ...