SK200A for Continuous Applications
SK200B2, MA & T Centrifugal Fans 
for Kitchens & Utility Rooms

Greenwood Air Management Ltd

Greenwood House

Brookside Avenue

Rustington

, West Sussex  BN16 3LF

T el: +44(0)1903 771021  F

ax: +44(0)1903 782398  

Email: [email protected]

Internet: www.greenwood.co

.uk

Environmental

Slotvent

GW logo col_MASTER

Environmental

Slotvent

In

st

a

lla

ti

o

n

In

st

ru

ct

io

n

s

SK200 install AW 3.6.10  4/6/10  01:58  Page 1

Содержание SK200A

Страница 1: ...nagement Ltd Greenwood House Brookside Avenue Rustington West Sussex BN16 3LF Tel 44 0 1903 771021 Fax 44 0 1903 782398 Email info greenwood co uk Internet www greenwood co uk Environmental Slotvent GW logo col_MASTER Environmental Slotvent Installation Instructions SK200 install AW 3 6 10 4 6 10 01 58 Page 1 ...

Страница 2: ...peration by pull cord remote switch or light switch SK200MA Dual speed operation with humidistat to low speed with adjustable overrun timer to further reduce humidity Manual operation by pull cord remote switch or light switch to full speed without overrun timer SK200T Single speed operation by pull cord remote switch or light switch with overrun timer for adjustable time period To clean or servic...

Страница 3: ...FITTING Cut out for surface mounted cabling A B Remove 2 screws Release cover with flat blade screwdriver A then apply thumb pressure to release catch in position B and gently pull free Fit 2 cover screws and tighten ensure corners clip into place Tighten 3 screws to secure Slide the top of the cover mounting clip into alignment Push cover in centre to engage centre clip Replace grille A B A B 12 ...

Страница 4: ...first fix backplate and screw in position Fit front cover and secure with 2 screws supplied Fit 100mm duct and external grille baffle for soffit or wall application making sure duct has a slight fall to exterior Note Remove backdraught shutter flap if using flexible duct Ceiling Mounting Flexible Ducting External Grille or Airbrick GG42 or RAB DO NOT DISTORT BACKPLATE WHEN FITTING See page 10 for ...

Страница 5: ...E Remove shutter flap if using flexible duct 4 3 SEE PAGE 10 FOR WIRING INSTRUCTIONS DO NOT DISTORT BACKPLATE WHEN FITTING SEE PAGE 10 FOR WIRING INSTRUCTIONS Template enclosed with fan must be used 4 3 NOTE Remove shutter flap if using flexible duct 6 7 Fit fan assembly as shown on page 5 pictures 10 11 12 SK200 install AW 3 6 10 4 6 10 01 58 Page 8 ...

Страница 6: ... SK200T Max 80W Mains Cable Sizes 2 or 3 core 0 75mm2 and 1 00mm2 Wiring Diagrams 1 3 5 8 35 mm 25 mm 6 mm 25 mm 3 Wire Connection 2 Wire Connection 1 2 1 2 3 2 4 6 Wiring Details for Fan Isolator Only 7 Rear of block Front of block L1 N L 5 6 Use self tapping screws Plasterboard thickness max 12mm min 9mm External wiring for pull cord only External wiring for operation in parallel with room light...

Страница 7: ...of purchase date 2 The Product has not been misused or handled carelessly or used on an inappropriate voltage supply 3 Repairs have not been attempted other than by Greenwood s service staff or authorised dealers and 4 In Greenwood s sole discretion the Product is found to be faulty If it were not found to be faulty the Product would be available for collection from the relevant Greenwood s premis...