Printed Circuit Board Connector Wiring Diagram
SiBE12-713
40
Printed Circuit Board Connector Wiring Diagram
1.1.2 FTK(X)S20~35C
Connectors
PCB(1) (Control PCB)
PCB(2) (Signal Receiver PCB)
PCB(3) (INTELLIGENT EYE sensor PCB)
Note:
Other designations
PCB(1) (Control PCB)
PCB(2) (Signal Receiver PCB)
1)
S1
Connector for fan motor
2)
S6
Connector for swing motor (Horizontal Flap)
3)
S7
Connector for fan motor
4)
S21
Connector for
centralized control
to 5 rooms
5)
S26
Connector for signal receiver PCB
6)
S27
Connector for control PCB
7)
S32
Connector for heat exchanger thermistor
8)
S35
Connector for INTELLIGENT EYE Sensor PCB
1)
S36
Connector for control PCB
1)
V1
Varistor
2)
JA
Address setting jumper
JB
Fan speed setting
when compressor is OFF on thermostat
JC
Power failure recovery function
∗
Refer to page 321 for more detail.
3)
SW7
Forced operation ON/OFF switch
4)
LED1
LED for operation (green)
5)
LED2
LED for timer (yellow)
6)
LED3
LED for HOME LEAVE operation (red)
7)
LED A
LED for service monitor (green)
8)
FU1
Fuse
(3.15A)
9)
RTH1
Room temperature thermistor
Содержание F-Series
Страница 1: ... Applied Models Inverter Multi Cooling Only Inverter Multi Heat Pump F Series SiBE12 713 ...
Страница 11: ...Introduction SiBE12 713 x ...
Страница 47: ...Specifications SiBE12 713 36 Specifications ...
Страница 113: ...Control Specification SiBE12 713 102 Function and Control ...
Страница 122: ...SiBE12 713 Instruction Operation Manual 111 FTK X S 20 25 35 C Names of parts Indoor Unit ...
Страница 235: ...Instruction SiBE12 713 224 Operation Manual ...
Страница 297: ...Check SiBE12 713 286 Service Diagnosis ...
Страница 316: ...SiBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points ...
Страница 330: ...SiBE12 713 Others 319 Part 8 Others 1 Others 320 1 1 Test Run from the Remote Controller 320 1 2 Jumper Settings 321 ...