SiBE12-713
Outdoor Unit
Removal Procedure
293
2. Disconnect the each
harnesses
1
Detach the fixing tape
for the electrical box
(cover).
2
Undo the 4 hooks at the
mark of the drip
proof cover.
3
Lift the cover up to
remove.
4
Disconnect the
connector for fan motor
[
S70
] from the PCB.
The shape of [S70] wire is
different depending on the
models.
Step
Procedure
Points