SiBE12-713
Outdoor Unit
Removal Procedure
295
8
Disconnect the
connector for overload
protector [
S40
].
9
Remove the OL wire
harness and the
compressor wire
harness together from
the partition plate.
10
Use long-nose pliers or
the like to pull out the
clamp.
Detach the clamp.
Just pull the push-mount
type out of position.
11
Disconnect the
connector for relay
harness of compressor.
Step
Procedure
Points
Clamp
(R6422)
Clamp
(R6423)
Содержание F-Series
Страница 1: ... Applied Models Inverter Multi Cooling Only Inverter Multi Heat Pump F Series SiBE12 713 ...
Страница 11: ...Introduction SiBE12 713 x ...
Страница 47: ...Specifications SiBE12 713 36 Specifications ...
Страница 113: ...Control Specification SiBE12 713 102 Function and Control ...
Страница 122: ...SiBE12 713 Instruction Operation Manual 111 FTK X S 20 25 35 C Names of parts Indoor Unit ...
Страница 235: ...Instruction SiBE12 713 224 Operation Manual ...
Страница 297: ...Check SiBE12 713 286 Service Diagnosis ...
Страница 316: ...SiBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points ...