SiBE12-713
Instruction
Operation Manual
219
Operate in the following order.
•
The timer is operated in the following two ways.
•
Programming the stop time (
)
.... The system stops
operating after the set time has elapsed.
•
Programming the start time (
)
.... The system starts
operating after the set time has elapsed.
•
The timer can be programmed a maximum of 72
hours.
•
The start and the stop time can be simultaneously
programmed.
TIMER MODE START/STOP
Press the TIMER MODE START/STOP button
several times and select the mode on the
display.
The display flashes.
For setting the timer stop .... “
”
For setting the timer start .... “
”
PROGRAMMING TIME
Press the PROGRAMMING TIME button and
set the time for stopping or starting the sys-
tem.
When this button is pressed, the time
advances by 1 hour.
When this button is pressed, the time
goes backward by 1 hour.
TIMER ON/OFF
Press the TIMER ON/OFF BUTTON.
The timer setting procedure ends.
The display “
or
” changes from flash-
ing light to a constant light.
Refer to figure 4 on page [1]
NOTE
•
When setting the timer Off and On at the same
time, repeat the above procedure from
to
once again.
When the timer is programmed to stop the system
after 3 hours and start the system after 4 hours, the
system will stop after 3 hours and then 1 hour later
the system will start.
•
After the timer is programmed, the display shows
the remaining time.
PROGRAM TIMER OPERATION
1
2
3
1
3
•
Press the TIMER ON/OFF BUTTON once again
to cancel programming. The display vanishes.
Observe the following precautions to ensure the
system operates.
•
Adjust the room temperature properly for a com-
fortable environment. Avoid excessive heating or
cooling.
•
Prevent direct sunlight from entering a room dur-
ing cooling operation by using curtains or blinds.
•
Ventilate the room regularly.
Using the unit for long periods of time requires
attentive ventilation of the room.
•
Keep doors and windows closed. If the doors and
windows remain open, room air will flow out and
cause to decrease the effect of cooling and heat-
ing.
•
Do not place other heaters directly below the
indoor unit.
They may deform due to the heat.
•
Never place objects near the air inlet and the air
outlet of the unit. It may cause deterioration in the
effect or stop in the operation.
•
Turn off the main power supply switch when it is
not used for long periods of time. When the main
power switch is turned on, some watts of electric-
ity is being used even if the system is not operat-
ing. Turn off the main power supply switch for
saving energy. When reoperating, turn on the
main power supply switch 6hours before opera-
tion for smooth running (Refer to MAINTE-
NANCE).
•
When the display shows “
”
(TIME TO CLEAN
AIR FILTER), ask a qualified service person to
clean the filters (Refer to MAINTENANCE).
7. OPTIMUM OPERATION
Содержание F-Series
Страница 1: ... Applied Models Inverter Multi Cooling Only Inverter Multi Heat Pump F Series SiBE12 713 ...
Страница 11: ...Introduction SiBE12 713 x ...
Страница 47: ...Specifications SiBE12 713 36 Specifications ...
Страница 113: ...Control Specification SiBE12 713 102 Function and Control ...
Страница 122: ...SiBE12 713 Instruction Operation Manual 111 FTK X S 20 25 35 C Names of parts Indoor Unit ...
Страница 235: ...Instruction SiBE12 713 224 Operation Manual ...
Страница 297: ...Check SiBE12 713 286 Service Diagnosis ...
Страница 316: ...SiBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points ...
Страница 330: ...SiBE12 713 Others 319 Part 8 Others 1 Others 320 1 1 Test Run from the Remote Controller 320 1 2 Jumper Settings 321 ...