SiBE12-713
Specifications
Specifications
35
1.4
Outdoor Units - Heat Pump
50Hz 230V
Note:
1. The data are based on the conditions shown in the table below.
Model
4MXS68F2V1B
Cooling
Heating
Cooling Capacity
kW
—
Power Consumption
W
—
Running Current
A
—
Casing Color
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Model
2YC45DXD
Motor Output
W
1,380
Refrigerant Oil
Model
FVC50K
Charge
L
0.65
Refrigerant
Type
R-410A
Charge
kg
2.6
Air Flow Rates
m³/min
H
52.7
46.4
M
49.4
44.5
L
43.5
16.3
cfm
H
1,861
1,638
M
1,744
1,571
L
1,536
576
Fan
Type
Propeller
Motor Output
W
53
Running Current
A
H: 0.20 / M: 0.16 / L: 0.10
H: 0.16 / M: 0.14 / L: 0.03
Power Consumption
W
H: 70 / M: 58 / L: 36
H: 55 / M: 48 / L: 10
Starting Current
A
6.2
Dimensions (H×W×D)
mm
735×936×300
Packaged Dimensions (H×W×D)
mm
797×992×390
Weight
kg
58
Gross Weight
kg
63
Operation Sound
dBA
48
49
Sound Power
dBA
61
—
Piping Connection
Liquid
mm
φ
6.4×4
Gas
mm
φ
9.5×2
, φ
12.7×2
Drain
mm
φ
18.0
Heat Insulation
Both Liquid and Gas Pipes
No. of Wiring Connection
3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length
m
60 (for Total of Each Room)
m
25 (for One Room)
Amount of Additional Charge
g/m
20 (30m or more)
Max. Installation Height Difference
m
15 (between Indoor Unit and Outdoor Unit)
m
7.5 (between Indoor Units)
Drawing No.
3D056404
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling
Heating
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
5m
Содержание F-Series
Страница 1: ... Applied Models Inverter Multi Cooling Only Inverter Multi Heat Pump F Series SiBE12 713 ...
Страница 11: ...Introduction SiBE12 713 x ...
Страница 47: ...Specifications SiBE12 713 36 Specifications ...
Страница 113: ...Control Specification SiBE12 713 102 Function and Control ...
Страница 122: ...SiBE12 713 Instruction Operation Manual 111 FTK X S 20 25 35 C Names of parts Indoor Unit ...
Страница 235: ...Instruction SiBE12 713 224 Operation Manual ...
Страница 297: ...Check SiBE12 713 286 Service Diagnosis ...
Страница 316: ...SiBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points ...
Страница 330: ...SiBE12 713 Others 319 Part 8 Others 1 Others 320 1 1 Test Run from the Remote Controller 320 1 2 Jumper Settings 321 ...