SiBE121135
Indoor Unit
Printed Circuit Board Connector Wiring Diagram
59
2.8
FDXS25/35E7VMB, FDXS50/60C7VMB
Connectors and
Other Parts
PCB (1): Control PCB
PCB (2): Display PCB
1) S1
Connector for AC fan motor
2) S7
Connector for AC fan motor (Hall IC)
3) S21
Connector for centralized control (HA)
4) S26
Connector for display PCB
5) S32
Connector for indoor heat exchanger thermistor
6) H1, H2, H3
Connector for terminal board
7) GND
Connector for terminal board (earth)
8) JA
Address setting jumper
∗
Refer to page 415 for detail.
9) JB
Fan speed setting when compressor stops for thermostat OFF
JC
Power failure recovery function (auto-restart)
Refer to page 418 for detail.
10) LED A
LED for service monitor (green)
11) FU1 (F1U)
Fuse (3.15A, 250V)
12) V1 (V1TR)
Varistor
1) S1
Connector for control PCB
2) SW1 (S1W)
Forced cooling operation [ON/OFF] button
3) LED1 (H1P)
LED for HOME LEAVE operation (red)
4) LED2 (H2P)
LED for timer (yellow)
5) LED3 (H3P)
LED for operation (green)
6) RTH1 (R1T)
Room temperature thermistor
Содержание 3MXS40K2V1B
Страница 187: ...SiBE121135 RA Indoor Unit Operation Manual 175 2 1 17 Quick Reference FTXG25 35 50JV1BW A Quick Reference ...
Страница 188: ...RA Indoor Unit SiBE121135 176 Operation Manual FTXS20 25K2V1B CTXS15 35K2V1B Quick Reference ...
Страница 189: ...SiBE121135 RA Indoor Unit Operation Manual 177 FVXG25 35 50K2V1B Quick Reference ...
Страница 246: ...SA Indoor Unit SiBE121135 234 Operation Manual 2 Start 5s 5s 5s 5s 5s End ...
Страница 413: ...SiBE121135 Outdoor Unit 80 90 Class Removal Procedure 401 7 Remove the sound blanket inner Step Procedure Points R10439 ...