SiBE121135
Indoor Unit Control (RA Models)
Function and Control
95
1.15 Inverter POWERFUL Operation
Outline
In order to exploit the cooling and heating capacity to full extent, operate the air conditioner by
increasing the indoor fan rotating speed and the compressor frequency.
Detail
When the [POWERFUL] button is pressed, the fan speed and target temperature are converted
to the following states for 20 minutes.
A
= 40 ~ 90 rpm (depending on the model)
Ex: POWERFUL operation in cooling
Note:
For Floor Standing Type: FVXG Series
POWERFUL operation is only available in RADIANT 1 (RADIANT operation with heating), it is
not available in RADIANT 2 (RADIANT operation only).
1.16 Multi-Colored Indicator Lamp / TIMER Lamp
Features
Wall Mounted Type: FTXG Series
Current operation mode is displayed in color of the lamp of the indoor unit. Operating status can
be monitored even in automatic operation in accordance with the actual operation mode.
The lamp color changes according to the operation.
∗
AUTO ........................................................Red / Blue
∗
DRY ..........................................................Green
∗
COOL ........................................................Blue
∗
HEAT ........................................................Red
∗
FAN ...........................................................White
∗
TIMER .......................................................Orange
Operation mode
Fan speed
Target temperature
COOL
H tap +
A
rpm
18°C
DRY
Dry rotating speed +
A
rpm
Lowered by 2 ~ 2.5°C
HEAT / RADIANT 1
H tap +
A
rpm
30 ~ 32°C
FAN
H tap +
A
rpm
—
AUTO
Same as cooling / heating in
POWERFUL operation
The target temperature is kept
unchanged.
(R13571)
Target temp.
Fan
A
rpm
18˚C
H tap
Set tap
20 minutes
It should be the lower limit of
cooling temperature.
It counts 20 minutes. also
in the remote controller.
POWERFUL
ON
POWERFUL
OFF
Ending condition: "or" in 1 to 3
1. After the lapse of 20 minutes.
2. Operation OFF
3. POWERFUL operation is OFF.
(R15294)
Multi-colored indicator lamp /
TIMER lamp
Содержание 3MXS40K2V1B
Страница 187: ...SiBE121135 RA Indoor Unit Operation Manual 175 2 1 17 Quick Reference FTXG25 35 50JV1BW A Quick Reference ...
Страница 188: ...RA Indoor Unit SiBE121135 176 Operation Manual FTXS20 25K2V1B CTXS15 35K2V1B Quick Reference ...
Страница 189: ...SiBE121135 RA Indoor Unit Operation Manual 177 FVXG25 35 50K2V1B Quick Reference ...
Страница 246: ...SA Indoor Unit SiBE121135 234 Operation Manual 2 Start 5s 5s 5s 5s 5s End ...
Страница 413: ...SiBE121135 Outdoor Unit 80 90 Class Removal Procedure 401 7 Remove the sound blanket inner Step Procedure Points R10439 ...