SiBE121135
SA Indoor Unit
Operation Manual
247
13
BRC1D528
Remote controller
4PW23717-1
Limit operation cannot be selected
Make sure you are not in program mode ( not
blinking); if required, press to quit program
mode.
Browse to the programmed actions using the
button, select the day you want to edit.
Press the button for 5 seconds; program mode is
enabled, the icon and selected action are blinking.
Select the "last action" you want to keep using the
button. All higher actions will be deleted.
Confirm the deletion by pressing the button for 5
seconds, OR confirm the deletion for the current and
the next day too by pressing the and
buttons simultaneously for 5 seconds.
NOTE
In the case above, if for example the last
action was 3, the programmed actions 4
and 5 will also be deleted (if they were
present).
Quit programming or browsing.
Press the and buttons simultaneously for 5
seconds; the icon will invert and disappear to
confirm deletion.
NOTE
Only use clear tepid water to moisten the
cloth.
Operation manual
The guidelines below might help to solve your
problem. If you cannot remedy the problem, consult
your installer.
No readings on the remote controller (display
blank)
Check if the mains power is still applied to your
installation.
Only is displayed
This indicates that the installation has just been
powered, please wait until
disappears.
The schedule timer does work but the
programmed actions are executed at the wrong
time (e.g. 1 hour too late or too early)
Check if the clock and the day of the week are set
correctly, correct if necessary (refer to "CLOCK
SETTING FUNCTION" on page 4).
I cannot enable the schedule timer (the icon
blinks for 2 seconds and disappears)
The schedule timer has not been programmed yet.
First program the schedule timer (refer to
"Programming the schedule timer" on page 10).
I cannot enable the schedule timer (the
icon
is displayed)
The schedule timer can not be enabled when a
centralised control is connected.
Limit operation is not available for cooling only
installations.
3
I WANT TO DELETE ONE OR MORE
PROGRAMMED ACTIONS
4
I WANT TO DELETE ALL PROGRAMMED
ACTIONS AT ONCE
The remote controller does not need maintenance.
Remove dirt with a soft damp cloth.
7. Maintenance
8. Troubleshooting
4PW23717-1
Содержание 3MXS40K2V1B
Страница 187: ...SiBE121135 RA Indoor Unit Operation Manual 175 2 1 17 Quick Reference FTXG25 35 50JV1BW A Quick Reference ...
Страница 188: ...RA Indoor Unit SiBE121135 176 Operation Manual FTXS20 25K2V1B CTXS15 35K2V1B Quick Reference ...
Страница 189: ...SiBE121135 RA Indoor Unit Operation Manual 177 FVXG25 35 50K2V1B Quick Reference ...
Страница 246: ...SA Indoor Unit SiBE121135 234 Operation Manual 2 Start 5s 5s 5s 5s 5s End ...
Страница 413: ...SiBE121135 Outdoor Unit 80 90 Class Removal Procedure 401 7 Remove the sound blanket inner Step Procedure Points R10439 ...