SiBE121135
Control Specification
Function and Control
107
4. Control Specification
4.1
Mode Hierarchy
Outline
There are 3 modes; normal operation mode, forced operation mode, and power transistor test
mode for installation and servicing.
Detail
Cooling Only Model
Heat Pump Model
Note:
Unless specified otherwise, a dry operation command is regarded as cooling operation and
a radiant operation command is regarded as heating operation.
Indoor fan operation cannot be made in multiple indoor units. (A forced fan command is
made during forced cooling operation.)
Determine Operation Mode
The system judges the operation mode command which is set by each room in accordance with
the procedure, and determines the operation mode of the system.
The following procedure is taken when the modes conflict with each other.
∗
1. The system follows the mode which is set first. (First-push, first-set)
∗
2. For the rooms where the different mode is set, standby mode is activated. (The operation
lamp blinks.)
(R14428)
Air conditioner control mode
Forced operation mode
Forced cooling operation
Power transistor test mode
Normal operation mode
Fan
Cooling (includes drying)
Stop (indoor unit: OFF)
Preheating operation
Discharging from capacitor
Stop
Air conditioner control mode
Forced operation mode
Forced cooling operation
Power transistor test mode
Normal operation mode
Fan
Cooling (includes drying)
Heating
Heating
Defrosting
Stop (indoor unit: OFF)
Preheating operation
Discharging from capacitor
Stop
(R14248)
Содержание 3MXS40K2V1B
Страница 187: ...SiBE121135 RA Indoor Unit Operation Manual 175 2 1 17 Quick Reference FTXG25 35 50JV1BW A Quick Reference ...
Страница 188: ...RA Indoor Unit SiBE121135 176 Operation Manual FTXS20 25K2V1B CTXS15 35K2V1B Quick Reference ...
Страница 189: ...SiBE121135 RA Indoor Unit Operation Manual 177 FVXG25 35 50K2V1B Quick Reference ...
Страница 246: ...SA Indoor Unit SiBE121135 234 Operation Manual 2 Start 5s 5s 5s 5s 5s End ...
Страница 413: ...SiBE121135 Outdoor Unit 80 90 Class Removal Procedure 401 7 Remove the sound blanket inner Step Procedure Points R10439 ...