80
-
14. SPECIFICATIONS
(Continued)
14.3 Initial Value and Setting Range
●
Initial Value and Setting Range of Parameters
Initial value
Setting range
CPVE-400(S-2)
CPVE-500(S-2)
·Initial condition
·Main welding condition
·Crater-fill condition
Current 100
A
30–450A
30-550A
Voltage 19
V
12–45V
12-50V
Fine adjustment of voltage
0
-30–30
ARC
Spot Time
3 sec.
0.1–10 sec.
ARC CHARACTERISTICS
0
-99–99
Memory Number for Welding Condition
1
1–30
●
Function
Initial Value
Setting Item
CPVE-400(S-2)
CPVE-500(S-2)
Crater Filler
OFF
OFF / ON / REPEAT / ARC SPOT
Shielding gas
CO
2
CO
2
/MAG/MIG/DC STICK
Wire Type
MILD STEEL SOLID
MILD STEEL SOLID / FLUX CORED
STAINLESS SOLID / FLUX CORED
Wire Diameter
1.2
0.8/0.9/1.0/1.2 0.8/0.9/1.0/1.2/1.4/1.6
Initial Current
OFF
ON / OFF
Welding Voltage Adjustment
INDIVIDUAL
SYNERGIC / INDIVIDUAL
●
Internal Function refer to section “10.2.1 Setting of Internal Function” for more details-
F
Function
Initial value
Setting range
F1 Fine adjustment of anti-stick(burnback) time
0
-50 (0.50 sec. decrement) –50 (0.50 sec.
incremental)
F2 Fine adjustment of anti-stick(burnback) voltage
0.0
-9.9–9.9 V
F3 Fine adjustment of slow wire feed
0.0
−
1.0–1.0 m/min.
F4 Switch of Auto/Semi-automatic mode
0
0 (semi-auto mode)/ 1(auto1)/ 2(auto2)
F5 External command 10 V MAX
OFF
ON(valid) / OFF(invalid)
F6 Setting of up-slope time
0.0
0–10.0 sec.
F7 Setting of down-slope time
0.0
0–10.0 sec.
F8 Setting of Result display holding time
20
0–60 sec.
F9 -
-
-
F10 Disabling Power saving function
OFF
ON (valid) / OFF (invalid)
F11
Setting of fine adjustment for welding condition
memory
OFF
ON (valid) / OFF (invalid)
F12 Setting of soft arc mode
OFF
ON (valid) / OFF (invalid)
F13 Setting of CONSTANT PENETRATION
OFF
ON (valid) / OFF (invalid)
F14 Switch of Wire feeding machine selection
0
0
:
CM-8201(22m/min)
1
:
CMXL-2301(18m/min)
2
:
CM-6201(22m/min)
F15 INITIAL CONDITION setting
OFF
ON (valid) / OFF (invalid)
F16 Gas pre-flow time
0.1
0 – 10 sec
F17 Gas post-flow time
0.4
0 – 10 sec
Wminfo