50
-
10. OPERATION
(Continued)
(2) After switching to the password setting mode, the left digital meter will display “Loc”, the
right digital meter will display “000” with the hundreds digit blinking. In this status, the
hundreds digit can be set through the parameter adjusting knobs ([4],[5]).
For example, the setting method for password “123” is as follows:
(3) Press DISPLAY CHANGE key[7] to shift digit blinking from hundred’s place to ten’s place.
In this status, the tens digit can be set through the parameter adjusting knobs([4],[5]).
(4) Press DISPLAY CHANGE key[7] again to shift digit blinking from ten’s place to unit’s place.
In this status, the units digit can be set through the parameter adjusting knobs ([4],[5]).
In this status, if pressing the DISPLAY CHANGE key again, digit blinking will return to the
hundreds digit.
(5) After completion of all digits, press the ENTER key[14] for confirmation. The left display
meter will display “Loc”, the right digital meter will display the newly set password “123”,
and the both display meters will be blinking alternately.
If the password is wrong, press any key other than ENTER key[14] to return to the
previous status, and then enter a correct password again.
(6) After confirmation of the correct password, press the ENTER key[14] again to complete
the password setting mode. Now the password has been set successfully.
Note that now it is not in the password lock state. To switch to the password lock state,
long press the ENTER key[14].