19
-
8. CONNECTION PROCEDURE AND GROUND FOR SAFETY USE
(Continued)
8.2 Connection at the Output Side of the Welding Power Source
CAUTION
In order to prevent occurrence of electromagnetic harm, refer to the
following items when connecting the welding cables. In case of
electromagnetic harm, refer to the following items again.
Reduce the length of the welding cables as much as possible.
Keep the welding cables close to the ground as much as possible.
Make the cable at the workpiece side parallel to the cable at the wire feeder side.
The grounding of the workpiece and welder shall not be shared by other.
Connection fault may damage the output connection terminals of the power source, so
please abide by the following points.
Please make insulating treatment to the part on the cable connection terminal
that protrudes from output terminal
Please follow below orders to connect cable to the output terminal.
Plain washer and spring washer cannot be used between output terminal and cable pressing
terminal
fixing terminal PW
screw
PW
SW
screw
fixing terminal
right wrong
output terminal
connection terminal
plain washer spring washer
hexagon socket screw
Insulating treatment
CAUTION
SW
Wminfo