10. OPERATION
(Continued)
10.1.2 Setting of Parameter
Select a welding condition by DISPLAY CHANGE key[7], then the digital meter will display the
corresponding condition value selected, and the LED corresponding to the condition will light up
simultaneously.
(1) Setting of INITIAL condition
INITIAL condition can be selected only when internal function “F15” is “ON” and “CRATER
FILLER” is set to “ON” or “REPEAT”. When INITIAL condition is selected, the digital meter will
display the setting value of INITIAL condition.
(2) Setting of MAIN condition
If MAIN condition is selected, the digital meter will display the setting value of MAIN condition.
(3) Setting of CRATER condition
CRATER condition can be selected only when “CRATER FILLER” is set to “ON” or “REPEAT”.
If CRATER condition is selected, the digital meter will display the setting value of CRATER
condition.
NOTE: The setting values for voltage, current and wire feed rate displayed are not the
actually measured output values. Use the values in the displays as approximations.
Welding current can be set directly by
WELDING CURRENT adjusting knob [4].
Welding voltage can be set directly by
WELDING VOLTAGE adjusting knob [5].
Select a parameter (display switches clockwise)
Part for welding parameter setting
LEDs indicate units
Digital meter
Part for display