10. OPERATION
(Continued)
2) When switched to DC STICK mode after 5 second, output voltage start
automatically. So, please shut off the power of the distribution box and contact
the output side before switching to DC STICK mode.
3) If wants to stop the DC output, push and hold down GAS key[1] for a few
seconds to switch to the other modes.
4) When switched to DC STICK mode, only the Welding current knob of the analog
remote control will work.
5) JOB MEMORY function and Power Saving function of fan are not useful in the
mode of DC STICK.
6) In the mode of DC STICK, no-load voltage always exits. Please prevent to get
an electric shock.
The representation for wire diameters of CPVE-500 are shown in below. The wire diameters of Ø0.9
and Ø1.4 are indicated by means of lighting two LED lamps.
Ø0.8 mode Ø0.9 mode Ø1.0 mode Ø1.2 mode Ø1.4 mode Ø1.6 mode
(0.8 and 1.0 lamps lighting) (1.2 and 1.6 lamps lighting)
When setting a combination is not existing in the table, abnormality of setting welding method will
occur, the digital meter “------” blinks, and the welding power source will stop operation automatically.
In addition, the LED corresponding to the wrong wire diameter or shielding gas will also blink.
For example, the current welding mode is “SOLID”, “MAG”, “Ø1.4”, when the WIRE TYPE is
changed form “SOLID wire” to “FLUX-CORED wire”, the LED for the mode of MAG shielding gas
blinks, which indicates this setting in the combination is incorrect. The abnormality will disappear
and welding operation can be carried out after properly setting, i.e., reselect a wire type by WIRE
TYPE select key or reset a shielding gas by GAS select key.