83
-
14. SPECIFICATIONS
(Continued)
Storage of Welding Condition
1) Press the SAVE key to switch to
a memory mode. The right display
meter will display a condition
number and the left display meter
will display the welding current
stored by the condition number.
2) Use the condition adjusting
knob to set a condition number.
“
- -
-” displayed by the left display
meter indicates the condition
number is empty. If other identifier
is displayed, it indicates that old
data will be overwritten when new
data is stored.
3) Press the ENTER key to
confirm each parameter value
stored by the condition number
specified.
4) Press the ENTER key again to
store the current welding condition to
the specified condition number.
Loading the Welding Condition
1) Press LOAD key to enter the load mode. The
right display meter will display a condition
number and the left display meter will display
the welding current of the condition number.
2) Use the parameter adjusting knob to set a
desired condition number. If the left display
meter displays
“
- - -
”
, it indicates the
condition number is empty.
3) Press the ENTER key to confirm each
parameter value of the welding condition.
4) Press the ENTER key again and the memory
data will be read out.
Setting of Function (internal function)
1) Hold down the DISPLAY CHANGE key for
a few second to enter function mode. Then
the left display meter will display a function
number, and the right display meter will
display the function status of the function
number.
2) Select a function number by turning the
CURRENT adjusting knob to set a function
number.
3) Set a status of the function by turning the
VOLTAGE adjusting knob.
4) Hold down the DISPLAY CHANGE key
again to exit the "function mode".
List of Abnormality Code
N
o.
Digital Meter
Classification of Abnormality
Left
Right
1
E- 000
Operation
Stop
2
E-
010
Torch switch off state waiting
3
E-
100
Control power supply error
4
E-
150
Excessive Primary Input Voltage
5
E-
160
Insufficient Primary Input Voltage
6
E- 200
Primary / secondary current detection
error
7
E-
210
Voltage Detection error
8
E-
220
Inverter Feedback error
9
E- 300
Thermal
overload
10
E-
700
Output Over Current error
11
E- 710
Input
Open-phase
Press the SAVE key
Reset a condition number
To read out data by the condition number
Press the SAVE key.
Press the LOAD key.
Press the LOAD key
Set the welding condition number
by the adjusting knob.
Press the ENTER key
Confirm parameter value by
the DISPLAY CHANGE key .
Press the ENTER key.
End of readout mode.
Press the SAVE key.
Discontinue
Discontinue
Press the SAVE key.
Press the LOAD key.
To memorize data by the condition number
Discontinue
Reset a condition number
Confirm parameter value by
SAY CHANGE key
Discontinue
Set a condition number by the
adjusting knob
Press the ENTER key
Press the ENTER key.
End of memory mode .
Press the SAVE key.
Wminfo