10. OPERATION
(Continued)
10.2.4 JOB MEMORY Function
The set welding conditions can be stored in the internal memory of the welding power source
by using the memory function for welding condition, and the stored data can be read at any
time to reproduce the welding conditions. Up to 30 welding conditions can be memorized.
NOTE: The stored data by the JOB MEMORY function for welding condition will not
include all of internal function parameters. These internal function parameters are
not limited to a single welding condition, but are applicable to all welding
conditions.
CAUTION
The welding conditions (electronic data) stored by this function are susceptible to
occurrence of static electricity, impact, repair, etc., and there is a possibility that the
storage contents may be changed or lost. BE SURE TO MAKE A COPY FOR IMPORTANT
DATA.
We shall not assume any responsibility for any change or loss of electronic information
resulting from repair, which you should note in advance.
After switching to a memory mode or read mode, any key other than SAVE key, LOAD key
and ENTER key will be unavailable. To back out of the memory mode or read mode, press
LOAD key [12] or SAVE key [13] respectively.
To copy a welding condition, first read the welding condition, and then save it with a different
condition number.
Note: W
hen an analog remote control is connected, the setting value of welding
current or voltage by the analog remote control will take precedence even if
a welding condition has been read.