xStack DES-6500 Modular Layer 3 Chassis Ethernet Switch User Manual
Appendix B
Upgrading Instructions for Release 3 Firmware (R3.00-B33)
For firmware release R3.00-B33, certain guidelines must be followed for proper installation of line cards and their appropriate
firmware.
Failing to follow these rules may result in inoperability of the switch or installed line cards.
Line Card Firmware Compatibility
The xStack DES-6500 chassis switch supports the following line cards:
DES-6504 12-port 100BASE-FX (SFF) Fast Ethernet Switch module
•
•
•
•
•
•
•
•
DES-6505 8-port 1000Base-SX SC Fiber Module
DES-6506 Patch Panel for 24 port RJ45
DES-6507 12-port 10BASE-T/100BASE-TX/1000BASE-T + Combo 2 SFP
DES-6508 16-port 10/100M Base-T module
DES-6509 12-port mini GBIC Fiber Module
DES-6510 24-port 10/100M RJ21 Module
DES-6512 2-port 10 GE XFP switch module
These line cards have various compatibilities with different CPU firmware runtime versions. See the following table for a better
understanding.
Runtime Code Version
Supported Line Card
R1.01-B37 DES-6507/DES-6509
R1.01-B40
DES-6505
/DES-6507/DES-6509
R1.20-B09 DES-6505/DES-6507/
DES-6508
/DES-6509/
DES-6510
R1.30-B02
DES-6504
/DES-6505/DES-6507/DES-6508/DES-6509/DES-6510
R1.40-B03 DES-6504/DES-6505/DES-6507/DES-6508/DES-6509/DES-6510
R2.00-B20 DES-6504/DES-6505/DES-6507/DES-6508/DES-6509/DES-6510
R2.50-B12 DES-6504/DES-6505/DES-6507/DES-6508/DES-6509/DES-6510/
DES-6512
R3.00-B33 DES-6504/DES-6505/DES-6507/DES-6508/DES-6509/DES-6510/DES-6512
In the previous table, the Runtime Code Version is the earliest firmware version that the corresponding cards listed in the
Supported Line Card column can utilize. For example, the DES-6507 and the DES-6509 are listed for every firmware and
therefore are compatible with every firmware release dating back to R1.01-B37. The DES-6505 starts with R1.01-B40 and is
compatible with every firmware release dating back to R1.01-B40, and so on.
Installing a line card in the chassis containing
unsupported firmware will result in a system boot-up failure for the chassis.
Line cards marked in bold denote recently added
firmware support for these line cards with the corresponding listed firmware.
All installed line cards must be using the same
firmware release runtime code as the chassis CPU, or compatibility problems will arise.
Precautions for Adding New Line Cards to the Chassis
Certain guidelines must be followed when attempting to add a new line card to the chassis.
1. Ensure the firmware version of the chassis will support the new line cards and their corresponding firmware.
2. Remove line cards which cause a compatibility issue before adding the new line cards. See the next section for more
information on line card compatibility.
3. Perform a system reset on the chassis before updating the firmware code of the new line cards. See the next section for
more information regarding updating firmware for the chassis and the Switch.
276
Содержание TM DES-6500
Страница 1: ...User Manual Product Model TM DES 6500 Modular Layer 3 Chassis Ethernet Switch Release 3 5 ...
Страница 215: ...xStack DES 6500 Modular Layer 3 Chassis Ethernet Switch User Manual Figure 7 2 Enter Network Password window 4 200 ...
Страница 333: ......
Страница 350: ......
Страница 353: ...9 Would you recommend your D Link product to a friend Yes No Don t know yet 10 Your comments on this product ...