Document Number: 002-10635 Rev. *I
Page
284 of 325
S6J3310/20/30/40 Series
Page
Section
Change Results
217
9.Electric
Characteristics
9.1.4.11.Low
Voltage
Detection
(External
Voltage)
Added
*2
and
*2
sentences as below:
Error)
Parameter
Symbol
Pin Name
Conditions
Value
Unit
Remarks
Min
Typ
Max
Detection voltage
(after trimming)
V
RDLAT
VCC12
*1
0.7841
0.8125
0.8410
V
When power-
supply voltage
falls
Typ±3.5%
Correct)
Parameter
Symbol
Pin Name
Conditions
Value
Unit
Remarks
Min
Typ
Max
Detection voltage
(after trimming)
V
RDLAT
VCC12
*1
0.7841
0.8125
0.8410
V
When power-
supply voltage
falls
Typ±3.5%
*2
*2: This detection voltage level setting is below the minimum operation assurance voltage .
Between this detection voltage and the minimum operation assurance voltage,
MCU functions are not guaranteed except for the low voltage detector.
Note that although the detection level is below the minimum operation guarantee voltage,
the LVD reset factor flag is set as the voltage drops below the detection level.
218
9.Electric
Characteristics
9.1.4.12.Low
Voltage
Detection
(Internal Voltage)
Added
*2
and
*2
sentences as below:
Error)
Parameter
Symbol
Pin
Name
Conditions
Value
Unit
Remarks
Min
Typ
Max
Detection voltage
(after trimming)
V
RDLAT
-
*1
0.844
0.875
0.906
V
When power-
supply voltage falls
Typ±3.5%
Correct)
Parameter
Symbol
Pin
Name
Conditions
Value
Unit
Remarks
Min
Typ
Max
Detection voltage
(after trimming)
V
RDLAT
-
*1
0.844
0.875
0.906
V
When power-
supply voltage falls
Typ±3.5%
*2
*2: This detection voltage level setting is below the minimum operation assurance voltage .
Between this detection voltage and the minimum operation assurance voltage,
MCU functions are not guaranteed except for the low voltage detector.
Note that although the detection level is below the minimum operation guarantee voltage,
the LVD reset factor flag is set as the voltage drops below the detection level.