208
9.Electric
Characteristics
9.1.4.6Multi-
Function Serial
Revised as below:
Error)
I
2
C timing (SMR:MD2-0=0b100)
(T
A
: Recommended operating conditions, Vcc5=Vcc53=5.0 V ±10%, V
CC
12=1.15V ±0.06V, V
SS
=0.0 V)
Parameter
Symbol
Pin Name
Conditions
Standard
Mode
High-Speed
Mode
Unit
Remarks
Min
Max
Min
Max
SCL clock frequency
f
SCL
SCL0, SCL1, SCL4,
SCL8 to SCL12,
SCL16 to SCL17
C
L
=50pF,
R=(Vp/I
OL
)
*1
0
100
0
400
kHz
Correct)
I
2
C timing (SMR:MD2-0=0b100)
(T
A
: Recommended operating conditions, Vcc5=Vcc53=5.0 V ±10%, V
CC
12=1.15V ±0.06V, V
SS
=0.0 V)
Parameter
Symbol
Pin Name
Conditions
Standard
Mode
Fast
Mode
Unit
Remarks
Min
Max
Min
Max
SCL clock frequency
f
SCL
SCL0, SCL1, SCL4,
SCL8 to SCL12,
SCL16 to SCL17
C
L
=50pF,
R=(Vp/I
OL
)
*1
0
100
0
400
kHz
Error)
*3: A high-speed mode I
2
C bus device can be used on a standard mode I
2
C bus system as long as the
device satisfies the requirement of "t
SUDAT
≥ 250 ns".
Correct)
*3: A fast mode I
2
C bus device can be used on a standard mode I
2
C bus system as long as the
device satisfies the requirement of "t
SUDAT
≥ 250 ns".
216
9.Electric
Characteristics
9.1.4.11.Low
Voltage
Detection
(External
Voltage)
Added
*5
and
*5
sentences as below:
Error)
Parameter
Symbol
Pin Name
Conditions
Value
Unit
Remarks
Min
Typ
Max
Detection voltage
(after trimming)
V
DLAT
VCC5
*1
3.86
*3
4.0
*3
4.14
*3
V
When power-
supply voltage falls
and detection level
is set initially
Typ±3.5%
2.51
*4
2.6
*4
2.69
*4
VCC3
*1
2.51
2.6
2.69
V
Correct)
Parameter
Symbol
Pin Name
Conditions
Value
Unit
Remarks
Min
Typ
Max
Detection voltage
(after trimming)
V
DLAT
VCC5
*1
3.86
*3
4.0
*3
4.14
*3
V
When power-
supply voltage falls
and detection level
is set initially
Typ±3.5%
*5
2.51
*4
2.6
*4
2.69
*4
VCC3
*1
2.51
2.6
2.69
V
*5: This detection voltage level setting is below the minimum operation assurance voltage (2.7V
*4
or 4.0V
*3
) .
Between this detection voltage and the minimum operation assurance voltage,
MCU functions are not guaranteed except for the low voltage detector.
Note that although the detection level is below the minimum operation guarantee voltage,
the LVD reset factor flag is set as the voltage drops below the detection level.