© 2018 Cyphre Security Solutions, LLC.
5 – 173
BT1 Security Appliance User Guide
5 About the IPMITool
5.11
Command: event
<predefined event number N>
Send a pre-defined test event to the System Event Log. The following events are
included as a means to test the functionality of the System Event Log component of
the BMC (an entry will be added each time the event Nn command is executed).
Currently supported values for n are:
1.
Temperature: Upper Critical: Going High
2.
Voltage Threshold: Lower Critical: Going Low
3.
Memory: Correctable ECC Error Detected
Note:
These pre-defined events will likely not produce "accurate" SEL
records for a particular system because they will not be
correctly tied to a valid sensor number, but they are sufficient to
verify correct operation of the SEL.
file <filename>
Event log records specified in <filename> will be added to the System Event Log.
The format of each line in the file is as follows:
<{EvM Revision} {Sensor Type} {Sensor Num} {Event Dir/Type} {Event Data 0} {Event
Data 1} {Event Data 2}>[# COMMENT]
Note:
The Event Dir/Type field is encoded with the event direction as
the high bit (bit 7) and the event type as the low 7 bits.
Example
0x4 0x2 0x60 0x1 0x52 0x0 0x0 # Voltage threshold: Lower Critical: Going Low
Confidential
Содержание BT1
Страница 2: ... This page intentionally left blank ...
Страница 8: ... 2018 Cyphre Security Solutions LLC vi This page intentionally left blank Confidential ...
Страница 122: ...4 106 2018 Cyphre Security Solutions LLC Confidential BT1 Security Appliance User Guide 4 System Setup ...
Страница 172: ...4 System Setup 4 156 2018 Cyphre Security Solutions LLC This page intentionally left blank Confidential ...
Страница 214: ...6 Troubleshooting the BT1 6 198 2018 Cyphre Security Solutions LLC This page intentionally left blank Confidential ...