57
E. Group and Global Broadcast
(1) Group Broadcast
User can use this function to control certain group of inverter at the same time. When
master send out group address data, the slave inverters will react when receive order,
but will not send any signal back to master.
(2) Global Broadcast
User can use this function to control all inverters at the same time. When master global
broadcast, all slaves inverters will react after receive order, but will not send any signal
back to master.
Group and Global broadcast address should be recognized refer to table as below, when
the group and global broadcast address is in use.
There are 240 addresses in total for inverter setting, which means it can connect up to
240 inverters at the same time, and provide 1 Global Broadcast address 15-group
address. Each group address can control up to 16 inverters, and user can set it.
Group
Individual
Address
Group address Global address
Group 1
1…16
241
0
Group 2
17…32
242
0
Group 3
33…48
243
0
Group 4
49...64
244
0
Group 5
65...80
245
0
Group 6
81…96
246
0
Group 7
97…112
247
0
Group 8
113...128
248
0
Group 9
129...144
249
0
Group 10
145...160
250
0
Group 11
161...176
251
0
Group 12
177...192
252
0
Group 13
193...208
253
0
Group 14
209...224
254
0
Group 15
225...240
255
0