14
B. Use PROG key to input procedure
(Cd01=0)
1
0.
0
0
PROG/
SET
C
d
0
0
READ
1
0.
0
0
1
0.
0
0
▲
1
0.
1
0
SET
1
0.
1
0
C
d
0
0
1
0.
1
0
READ
C
d
0
0
Notice:
Indicate 7- segment LED flash.
§
Cd01
Setting procedure of frequency (Selective range 0~6)
The function cannot be modified during revolution.
Setting procedure of frequency is to select either panel key or external analog signal.
Cd01=0 Set frequency on operation panel, as the above items A-C.
Cd01=1 Set frequency by terminal In2 DC 0~10V/5K
Ω
VR
Cd01=2 Set frequency by terminal In1 DC 4~20mA
Cd01=3 Set frequency by terminal In2 DC 0~10V/5K
Ω
VR hysteresis
Cd01=4 Setting from terminal In1, input DC4~20mA hysteresis
Cd01=5 Setting value input by VR of keypad
Cd01=6 Set frequency by Multi-step function mode
Содержание CT-2000ES