31
§
Cd63
Start frenquency of auto voltage compensation
(
Settable range 3.0
~
20.0HZ
)
The function cannot be modified during revolution.
This function is the point of motion to assume auto compensation voltage start
frenquency.
This function accommodate the content of Cd03
、
Cd52
§
Cd64
Dynamic braking range (Settable range 0-1)
This function cannot be adjusted during revolution.
Cd64 = 0 Dynamic braking can be active during acceleration, deceleration and
constant speed.
Cd64 = 1 Dynamic braking can be active during acceleration and deceleration, but
not active during constant speed operation.
§
Cd65
Instant initial field time (Settable range 1-7)
This function cannot be adjusted during revolution
This function is to adjust instant initial field current of motor. Shorter of the time is
higher of the field current.
Cd65
Instant initial field
time
1
64mS
2
128mS
3
256mS
4
512mS
5
1024mS
6
2048mS
7
4096mS