39
§
CE63
Integral gain (settable range 0.0~360.0 sec)
PID control and associated gain (I).
§
CE64
Differential gain (settable range 0.0~10.0 sec)
PID control and associated gain (D).
§
CE65
Integral output limit (settable range 0~100 %)
Set % a unit as output limit of the Integral control. 100% is maximum frequency output.
§
CE66
PID output limit (settable range 0~100 %)
Set % a unit as output limit of the PID control. 100% is maximum frequency output.
§
CE67
PID control target value 1 (settable range 0~100.0 %)
This parameter defines the percentage of target value when PID control.
§
CE68
PID output delay time
(
settable range 0
~
10 sec
)
Set PID output delay time.
§
CE69
PID offset adjust
(
settable range 0
~
200%
)
Set % a unit as PID output offset. 100%is central point.
§
CE70
PID output gain
(
settable range 0
~
25
)
Set enlarge magnification of PID output.
§
CE74
P control status selection
(
settable range 0
~
1
)
P
、
I
、
D controller is individual controller separately when setting value is 0.
P controller is in front of I, D controller when setting value is 1 (an error passes through
P controller then enter into I,D controller).
§
CE78
PID output characteristic
selection
(
settable range 0
~
1
)
Set PID output inverse function, inverting when set 1.
§
CE79
PID control selection
(
settable range 0
~
4
)
0 : PID disable
1 : PID outpout is inverter frequency output, D control error.
2 : PID outpout is inverter frequency output, D control feedback.
3 : PID output is corrective value of inverter frequency output
(
accede
main frequency),
D control error.
4 : PID output is corrective value of inverter frequency output
(
accede
main frequency),
D control feedback
。
Содержание CT-2000ES